background image

SEP 

60

ST

Single Use 

Condensate Cleaner

www.sepura-technologies.com

installation manual

installation

1

Before Starting Assembly, please
read the following:

SEP 60 ST is a single-use product. It should
be replaced as directed to ensure its vital
environmental and legally protective
functions are performed correctly.

SEP 60 ST has been designed to clean
condensate from a compressor system of
up to 60cfm (1.7m3min) to better than
10ppm oil-in-water; suitable for discharge
to a sewer. 

Note: 

This is generally 

well below the accepted level, but it 
is the users responsibility to ensure 
compliance with local regulations.

Other size inlet ports are availble as shown

above. Please specify when ordering.

2

Fix the wall plate vertically on a
suitable wall or the compressor
cabinet. Isolate the compressor
and look out for cables and pipes
when drilling.

3

Slide the SEP60 on to the plate,
with the venting flutes at the top.

Connect all drain points, insert tube
into push fitting in the inlet (top).

• 6mm tube for metric 

• 

1

/

4

” tube for imperial

INLET 

Connect tube into outlet fitting and
feed to drain (side). Ensure a
steady fall from outlet point to
drain with no kinks or tight bends.

• 10mm tube for metric
• 

3

/

8

” tube for imperial

Important Always use an automatic drain.

Set timers to short open periods of one second or less. 

NEVER

use manual drains which could flood the separator, forcing partially treated or untreated condensate to be discharged.

6

5

>

>

>

>

>

>

OUTLET

Anti-siphon Vent

(Do NOT block)

4

>

8mm

1/4”

5/16”

Top Inlet Port

The unit comes shipped with a 

6mm inlet port as standard