3 Command Line Reference
snc
gnc
setNtpClient
getNtpClient
Mode
Server (40)
on
off
default
RxControl: Navigation > Receiver Operation > Timing
Use this command to configure the retrieval of the time from an external NTP time server.
Getting the time from an external source can help the receiver to perform some sanity checks
on the signal received from the GNSS satellites. It is fully optional, except in case of strict
OSNMA operation (see the
command).
If
Mode
is
on
, the receiver will attempt to get the current time from the NTP server specified
with the
Server
argument.
The
Server
argument accepts a host name or a raw IP address. If set to "
default
", a server
is automatically selected by the receiver.
Accessing the NTP server requires the receiver to have access to the Internet. If the receiver
is not connected to a network, the access fails with no error message.
Example
COM1>
snc, on, pool.ntp.org<CR>
$R: snc, on, pool.ntp.org
NtpClient, on, pool.ntp.org
COM1>
162
Содержание PolaRx5TR
Страница 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Страница 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Страница 108: ...3 Command Line Reference COM1 gca Ch05 CR R gca Ch05 ChannelAllocation Ch05 G01 auto 0 16000 COM1 108 ...
Страница 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Страница 147: ...3 Command Line Reference PVTMode Static StandAlone SBAS DGPS RTKFloat RTKFixed Cartesian1 COM1 147 ...
Страница 218: ...3 Command Line Reference COM1 esoc COM1 MeasEpoch CR R esoc COM1 MeasEpoch SBFOnce COM1 MeasEpoch COM1 218 ...
Страница 237: ...3 Command Line Reference COM1 237 ...
Страница 251: ...3 Command Line Reference Event type Command etime 1588343730 before 1440 after 1440 Planned Disk DiskEvent COM1 251 ...
Страница 279: ...3 Command Line Reference COM1 279 ...
Страница 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...