_____________________________________________________ 1 PolaRx4_PRO and PolaRx4TR_PRO
PolaRx4 Product Family Hardware Manual v2.0.0
16
Cable Name: CBLe_USB
Part #:
201202
USB cable to be connected to the COM3-4/USB connector.
Cable Name: CBLe_ETH_MS
Part #:
200418
Ethernet to hub/switch (straight) (RJ45). To be connected to the ETH connector.
Cable Name: CBLe_ETH_MX
Part #:
200417
Ethernet to PC (crossed) (RJ45). To be connected to the ETH connector.
Cable Name: CBLe_PWR_OE
Part #:
200422
Open-ended cable for the PWR connector (see pinout in section 1.2.8).
Pin#
Function
Wire Color
1
Power
Blue and green (these two wires are both connected to Pin#1)
2
ON/OFF
Red
3
GND
Black and Purple (these two wires are both connected to Pin#3)
1.7
Internal Logging on SD Memory Card
The receiver incorporates a SD memory card for internal logging. Refer to the “
How-to…
” section of
the Firmware User Manual to learn how to use this feature.
To prevent data corruption, logging is protected against accidental power outages. There is no need to
unmount the SD memory card before switching off the receiver.
1.8
Stand-By Mode
The receiver can be put in stand-by mode by entering the command “
exePowerMode, StandBy
”
(see Command Line Interface Reference Guide).
Waking up from stand-by mode is done by sending characters to the COM1 serial port.
For remotely-operated receivers, make sure that COM1 is remotely accessible before putting the receiver
in stand-by mode.
1.9
Applicable Software Package
PolaRx4_PRO and PolaRx4TR_PRO are compatible with Septentrio’s SSRC4 Software Packages.