3.4. HOW TO CONFIGURE SBF AND NMEA OUTPUT
Figure 3-9:
Connect to the Web Interface of the AsteRx-U MARINE Fg over WiFi
using the IP address
192.168.20.1
on any web browser
3.4 How to con
fi
gure SBF and NMEA output
The AsteRx-U MARINE Fg can output position and GNSS data in both standard NMEA format
and Septentrio’s proprietary compact binary format SBF. This following sections detail how
to con
fi
gure connections to other devices in order to send data.
3.4.1 Output over a serial COM connection
The AsteRx-U MARINE Fg can be connected via a serial COM cable to an RS-232 compatible
secondary device
Step 1: Con
fi
gure the serial COM port
The COM port of the AsteRx-U MARINE Fg should be con
fi
gured with the same baud rate
and
fl
ow control setting of the coupled device. These settings can be con
fi
gured via the
‘
Communication
’
tab as shown in Figure 3-10. In this example, COM3 is set with a speed of
19200 baud.
2
The performance at the highest setting of 460800 baud has not yet been fully validated.
21