MARINE BATTERY CHARGERS
Voyager Elite Series
Installation/ Operation
Linear Devices Corporation
dba Sentry
11126 Air Park Rd, Suite G Ashland, VA 23005 December 2017
www.sentrychargers.com
Phone: 804-368-8428
Fax: 804-368-8438
Страница 1: ...ERY CHARGERS Voyager Elite Series Installation Operation Linear Devices Corporation dba Sentry 11126 Air Park Rd Suite G Ashland VA 23005 December 2017 www sentrychargers com Phone 804 368 8428 Fax 80...
Страница 2: ...6 Connection Details 7 9 AC Cables and Circuit Breaker Sizing 10 DC Cables and Fuses 11 12 Setting Charging Curve and Battery Types 12 15 Operation of Battery Temp Sensor 16 LED Display Indicators 17...
Страница 3: ...m It must not be installed in an airtight or poorly ventilated compartment The ventilation inlets must not be obstructed Clearance of at least 4 10 cm must be allowed around the housing to guarantee a...
Страница 4: ...hen in operation take particular care that this device is not subjected to conducted or radiated interference at levels higher than the legal limits otherwise malfunctions may occur e g device too clo...
Страница 5: ...teries these may only be replaced by a qualified person to avoid any danger The main power supply must be disconnected cable or switch The DC or BAT supply on the battery must also be disconnected to...
Страница 6: ...he sides allowing the air needed for ventilation to flow in and out The circulation and convection direction of the air inside the charger is from right to left viewed from the front of the Product CO...
Страница 7: ...7 CONNECTION DETAILS...
Страница 8: ...re color code red CHARGE SELECT Charge curve and battery charging mode selector 10 positions from 0 to 9 refer to curve settings p14 BATTERY FUSES Battery Protection fuses on the DC supply EXT COM 1 E...
Страница 9: ...9 Example of connection on the basis of 3 distinct sets of batteries Important Check for proper torque and crimp of connections and terminals...
Страница 10: ...ature a cut off device with differential protection GFCI to specifically Protect individuals against electric shock The circuit breaker s sensitivity must be 30mA Its current capacities comply with th...
Страница 11: ...sure that you comply with the following recommended cross sections Charger Length 2m 6ft Length between 3 capacity and 5m 10 to 16ft 12V 60A 25mm2 AWG3 35mm2 AWG2 12V 90A 35mm2 AWG2 50mm2 AWG0 1 24V 4...
Страница 12: ...ple Internal charger External battery Charger fuse fuse capacity BAT supply for DC supply each battery 12V 60A 3 x 25A 32V rapid 80A 32V rapid mini automotive fuse 12V 90A 4 x 30A 32V rapid 100A 32V r...
Страница 13: ...head screwdriver CAUTION It is important to note that the use of an inappropriate charging cycle for the battery technology may extensively impair or even damage the latter This is particularly true...
Страница 14: ...OST 14 2V 28 4V lead V FLOAT 13 6V 27 2V 2 Lead V BOOST 14 8V 29 6V calcium V FLOAT 13 8V 27 6V 3 Delphi V BOOST 15 4V 30 8V type V FLOAT 13 8V 27 6V Charge curve Op V BOOST 14 8V 29 6V 4 tima V MAX 1...
Страница 15: ...2V 28 4V Sealed V FLOAT 13 6V 27 2V lead Charge curve 7 GEL V BOOST 14 4V 28 8V AGM V FLOAT 13 8V 27 6V Charge curve 8 Power V FLOAT 13 6V 27 2V supply Charge curve LiFeSo4 9 inte V FLOAT 14 4V 28 8V...
Страница 16: ...al a service house battery as a general rule The 2 wires are connected to the TEMP SENSOR connector on the charger board not polarity sensitive The compensation level is around 25mV per C for a 24V ba...
Страница 17: ...se The voltage is maintained and the amperage is reduced until the battery returns to a level of charge approaching 100 This phase is limited to a period between 30 minutes and 4 hours depending on th...
Страница 18: ...N charge from 80 ABS to 100 PHASE End of the equali zation cycle within POWER ON ABS a period of 30 minutes FLOATING Charging cycle POWER ON completed PHASE charge at 100 FLOAT Main voltage fault exce...
Страница 19: ...Automatic restart TEMP SENSOR after a min delay FAULT for 30 seconds BAT subject to disappearance of the fault Charging voltage fault excessively high or abnormally low OUTPUT VOLTAGE Automatic resta...
Страница 20: ...3x32 6 3x32 fuse mm mm mm mm mm BATTERY CHARGING CHARACTERISTICS Number of 3 independent supplies outputs Number 10 charging cycles from 0 to 9 setting of by means of a dial cycles Charge In general...
Страница 21: ...Ripple 1 BW 20MHz Maxi 60A 90A 40A 60A 100A mum 5 5 5 5 5 current 3 x F30A 4 x F30A 5 x 30A minia minia 3 x F25A minia Supply ture ture miniature automo ture fuse DC automo automo tive automo tive ti...
Страница 22: ...g Wall mounted housing in painted aluminium Protection IP20 rating Mounting Using 4 x 8 4mm screws Overall dimen 125 x 340 x 360 mm 190x340x 360 sions Depth x 4 9 x 13 4 x 14 2 inches 7 5x13 4x 14 2 W...
Страница 23: ...23 Dimensions 12V 60A 12V 90A 24V 40A 24V 60A 24V 100A Height A 14 2 inch 360 mm Width B 13 4 inch 340 mm Depth C 4 9 inch 125 mm 190 mm 7 5 inch...
Страница 24: ...ons or irreversible damage to the equipment Powering the device from an unsuitable power source example supply voltage that is too high Accidental original main supply surge or lightning strike genera...