background image

1

Control Station

How to Use Your

Sentrol Security System

ZXLCD

AWAY

STAY

NIGHT

1

2

3

4

5

6

7

8

9

CLEAR

0

ENTER

VIEW INFO

ALM MEM

EVENT LOG

BYPASS

DELAY ARM

CHIME

RST SMOKE

TEST

PROGRAM

QUIT

ACCESS

INSTANT

HOME

NEXT

D

OFF

CANCEL

Содержание ZX440F

Страница 1: ...ion How to Use Your Sentrol Security System ZXLCD AWAY STAY NIGHT 1 2 3 4 5 6 7 8 9 CLEAR 0 ENTER VIEW INFO ALM MEM EVENT LOG BYPASS DELAY ARM CHIME RST SMOKE TEST PROGRAM QUIT ACCESS INSTANT HOME NEX...

Страница 2: ...unication to the Central Station is intact 5 Motion detectors are designed to detect specific types of motion within a defined area Be sure that you understand which areas are protected and under what...

Страница 3: ...Selective Bypass Unbypass 15 Removing Bypass 16 Force Arming 17 Turning Your System ON Using Two Button Double Press 17 Exit ON 18 Automatic ON 18 Delay Automatic ON 18 Keyswitch Operation 19 Access O...

Страница 4: ...the Zone Names 43 Multi Area Operation 45 Common Area Operation 46 Fire Detection 47 Introduction 47 When an Alarm Occurs 47 Resetting Smoke Detectors 48 Developing An Evacuation Plan 48 Fire Preventi...

Страница 5: ...ed are optional and may not be programmed in your particular system If you have questions concern ing the features on your system consult your Security Company Representative The LCD Control Station A...

Страница 6: ...window monitor ON or OFF Reset Smoke Key Resets all smoke detectors in alarm Test Key Allows you to perform system testing Program Key Used to enter the programming mode Access Key Used to activate a...

Страница 7: ...keys activate the auxiliary alarms Fire Police Medical Consult with your Security Company Representative for details Bedtime selected door window and interior sensors are ON No one at home total prote...

Страница 8: ...Display OPERATING YOUR SYSTEM NOTE To save power the LCD Control Station display will dim after four 4 minutes of no keypresses or sounder activity Press any key to turn the display back ON A1 READY T...

Страница 9: ...you exit during the last 10 seconds of countdown time the timer will restart the countdown once If you turn your system ON in the AWAY mode and you do not exit the countdown will begin again only onc...

Страница 10: ...t is NOT flashing you can stop the false alarm from being reported If the Armed Status Indicator light is flashing then the false alarm has been reported and you need to contact the Central Station Wh...

Страница 11: ...mpt The prompt may show STAY or NIGHT 2 Enter passcode 3 The Control Station will then begin exit countdown time It is safe to exit the building during the countdown time If you exit during the last 1...

Страница 12: ...d ON or if it was turned OFF Viewing and Printing The Event Log The Event Log is a record of the activities of your security system You may print the Event Log if you have a printer attached To enter...

Страница 13: ...play the last event that occurred Press To scroll backwards through the event log To scroll forward To return to the Ready mode If 2 is selected the recorded information will be sent to the attached p...

Страница 14: ...ss to intentionally bypass all open zones 1 Press The Control Station will display 2 Enter passcode The Control Station will display 3 Press to bypass all open zones then press The Control Station wil...

Страница 15: ...play the zone that was bypassed unbypassed and then return to the zone selection display Repeat step 3 for each zone you wish to bypass or unbypass See Protection Zones for a list of zone numbers and...

Страница 16: ...Control Station will briefly display then returns to the zone selection display 4 Press to save changes or to cancel changes After saving any changes the Control Station will return to the READY prom...

Страница 17: ...5 seconds press the same key that was pressed in Step 1 above The Control Station will briefly display Turning Your System ON Using Two Button Double Press Your system may be programmed to quickly tur...

Страница 18: ...O NOT enable for UL Listed Systems This feature turns your system ON at a scheduled time daily Your Control Station will periodically display a visual warning and sound an audible warning each minute...

Страница 19: ...system will be turned ON in the AWAY mode only Access Output This system is not UL Listed for Access Control To activate an Access Output device or door strike 1 Press The Control Station will displa...

Страница 20: ...hich Control Stations have the panic keys enabled and the sound for each key An audible alarm may result To silence the alarm press the Off Cancel key and then enter your passcode User On Premise When...

Страница 21: ...sal Output OFF ON Press then for quick access Press then to turn an output OFF ON ex room light Press then to turn an output OFF ON ex basement light Press then to turn an output OFF ON ex lamp or tel...

Страница 22: ...er passcode The Control Station will display the alarm type and the source of alarm The ZX440F will alternate this display with the time and date that the alarm occurred If more than one zone or keypa...

Страница 23: ...1 Press The Control Station will display 2 Enter passcode After you silence the trouble sounder the Control Station display will alternate between the system status and the trouble message As long as...

Страница 24: ...ned listen for an audible and visual indication to occur at the Control Station indicating the sensor is working properly When all sensors have been opened return to the Control Station FOR TESTS ENTE...

Страница 25: ...tery has been installed Your battery is automatically tested periodically To perform a battery test 1 Press The Control Station will display 2 Enter passcode The Control Station will display 3 Press I...

Страница 26: ...ay 2 Enter passcode The Control Station will display 3 Press The audible will sound for several seconds The Control Station will display Notify your neighbors before you test the bell BELL TEST FOR TE...

Страница 27: ...nter passcode The Control Station will display 3 Press The Control Station will briefly display 4 If the test passes the Control Station will sound four 4 beeps when the test is completed The Control...

Страница 28: ...Station will display 2 Enter passcode The Control Station will display 3 Press The Control Station will briefly light all of its indicators AWAY STAY and NIGHT and display KEYPAD TEST FOR TESTS ENTER...

Страница 29: ...tically turning ON for the scheduled time for that day only 7 Cancelling Exit ON Cancels the system from automatically turning ON for Today 10 minutes after you leave the premises for that day only 8...

Страница 30: ...ay 3 Press The Control Station will display 4 Set the new time and date See example Example To set the clock to 2 15 pm on June 17 1997 Press 2 15 pm Press June 17 1997 5 Press to start over if a mist...

Страница 31: ...rn ON each day A Setting the Security Level To program the Automatic ON feature 1 Press The Control Station will display 2 Enter passcode The Control Station will display 3 Press The Control Station w...

Страница 32: ...ednesday 16 Thursday 32 Friday 64 Saturday Example To have your system automatically turn ON for Monday Tuesday and Saturday add 2 4 64 Enter the value 70 8 The Control Station will display Press for...

Страница 33: ...ation Day of the Week 3 hour on Sunday 5 hour on Monday 7 hour on Tuesday 9 hour on Wednesday 11 hour on Thursday 13 hour on Friday 15 hour on Saturday Steps 12 15 must be repeated for each day of the...

Страница 34: ...minute on Thursday 14 minute on Friday 16 minute on Saturday Steps 16 19 must be repeated for each day of the week you selected 16 The Control Station will display Enter location number from chart abo...

Страница 35: ...on the scheduled day Contact your Security Company Representative for more details There are five items to be programmed A Setting the User ID to be monitored B Day s of week to monitor C Time frame f...

Страница 36: ...ues below for those days selected Value Day of the Week 1 Sunday 2 Monday 4 Tuesday 8 Wednesday 16 Thursday 32 Friday 64 Saturday Example To set up monitoring for Monday Wednesday and Friday add 2 8 3...

Страница 37: ...ow cannot cross over the midnight boundary Example If the scheduled time is 3 00 pm and the time frame given to enter the passcode is from 2 30 pm until 3 30 pm you need to enter a value of 30 12 The...

Страница 38: ...0 hour on Wednesday 12 hour on Thursday 14 hour on Friday 16 hour on Saturday Steps 16 19 must be repeated for each day of the week you selected 16 The Control Station will display Enter location numb...

Страница 39: ...sday 13 minute on Thursday 15 minute on Friday 17 minute on Saturday Steps 20 23 must be repeated for each day of the week you selected 20 The Control Station will display Enter location number from c...

Страница 40: ...ay 3 Press The Control Station will display 4 Enter the User ID 1 50 that you wish to program change 5 Press 6 Enter new four digit passcode Repeat above steps for each passcode to be programmed or pr...

Страница 41: ...ncel Automatic ON for today 1 Press The Control Station will display 2 Enter passcode The Control Station will display 3 Press If Automatic ON was programmed for today the Control Station will display...

Страница 42: ...activity detected you may cancel it for today only To cancel Exit ON for today 1 Press The Control Station will display 2 Enter passcode The Control Station will display 3 Press If Exit ON was program...

Страница 43: ...n Zones for a list of zone numbers 5 The Control Station will display the zone number selected on the first line and the zone name to be programmed on the second line Press the key associated with eac...

Страница 44: ...sor back one position Used to move the cursor forward one position Key Character Available ZX440F PROGRAMMING 1 2 3 4 5 6 7 8 9 0 6 Press to start over if a mistake is made or press to save the zone n...

Страница 45: ...e an area selection for Area 1 Area 2 or both for any operation test or programming that is performed When the Control Station is displaying the system status it will alternate between the Primary and...

Страница 46: ...is disarmed the common area also is disarmed Faulted common area zones may be viewed on all Control Stations Arming and disarming operations are the same as previously described except that when you a...

Страница 47: ...he zone that caused the alarm To silence the alarm press the Off Cancel key and enter your passcode If you silence a Fire Alarm and the Control Station goes into Alarm Memory Mode see Alarm Conditions...

Страница 48: ...importance in the prevention of fire An evacuation plan should be established BEFORE a severe situation arises Your security system may or may not contain fire detection and notification equipment Mak...

Страница 49: ...minated from the home In Case Of Fire Leave immediately Do not stop to pack or search for valuables In heavy smoke hold your breath and stay low crawl if necessary The clearest air usually is at the f...

Страница 50: ...on bedroom windows Most fire departments supply the decals Become familiar with the distinctive sounds of your Fire alarm and Burglar alarm signals Supervisory Alarm Fire Trouble If a trouble conditio...

Страница 51: ...ion devices interior door contacts and under carpet sensors designed to surprise the intruder Keypad A generic term for the Control Station Latch Key Supervision Monitors the entry of a passcode accor...

Страница 52: ...y time for STAY and NIGHT arms Seconds of entry time Delay 1 for Zone s Seconds of entry time Delay 2 for Zone s Seconds of pre alarm time Control Station Location Circle the Control Stations that hav...

Страница 53: ...e Press ON Keyswitch User On Premise Two Button ON Household Fire Intrusion Features Enabled SYSTEM REFERENCE GUIDE The lockout is a temporary measure that affects only the Control Station in use for...

Страница 54: ...01 sensing devices on windows in the master bedroom to zone 02 and so on For your convenience a chart has been provided below which may be used to record the specific protection points that have been...

Страница 55: ...55 NOTES Notes...

Страница 56: ...ry UL Household Fire Warning System A General Information Insured s Name and Address Insurance Co Policy No Sentrol Security System Type of Alarm Burglary Fire Both Installed by Serviced by B Notifies...

Страница 57: ...ning Room Hall Other F Burglary Detecting Device Locations Front Door Basement door All Exterior Doors Rear Door 1st Floor windows All Windows Interior Locations Other All Accessible Openings Includin...

Страница 58: ...t interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and o...

Страница 59: ...59...

Страница 60: ...60 64812855A SENTROL Sentrol reserves the right to change specifications without notice 1998 Sentrol...