EXAMPLE 2:

EXAMPLE 2:

EXAMPLE 2:

EXAMPLE 2:

EXAMPLE 2:

In a single family dwelling with Zones 1, 2, 3, 4

protecting the interior of the dwelling, and zones 5, 6, 7, 8 protecting
its exterior, Group 1 can be set to 1, 2, 3, 4. This allows the owner
(with a minimum of keystrokes) to arm the exterior and bypass the
interior of the dwelling. This also frees the user from having to
remember all interior zones and inadvertently bypass an exterior
zone.

8.52

8.52

8.52

8.52

8.52 ZONES ASSIGNED TO KEYPAD

ZONES ASSIGNED TO KEYPAD

ZONES ASSIGNED TO KEYPAD

ZONES ASSIGNED TO KEYPAD

ZONES ASSIGNED TO KEYPAD

This programming function allows the flexibility to assign any
zone(s) to any keypad(s). Assigning zones to keypads performs two
functions. The keypads will only display the status of the zones that
are assigned to that keypad. Remember that in partitioning using
common zone(s) do not assign common zones to any keypad.

Example, if keypad 2 is assigned zones 2, 3, and 4, and zone 5 is
violated, keypad 2 will NOT display the status of zone 5. The second
purpose of this assignment is to control the four area bells (these bell
outputs are located on the status module, see item 30 group 3).
Zones assigned to keypad areas 1-4 will activate bell module
outputs 1-4 respectively.

8.53

8.53

8.53

8.53

8.53 ZONE DESCRIPTIONS (16 CHARACTERS EACH)

ZONE DESCRIPTIONS (16 CHARACTERS EACH)

ZONE DESCRIPTIONS (16 CHARACTERS EACH)

ZONE DESCRIPTIONS (16 CHARACTERS EACH)

ZONE DESCRIPTIONS (16 CHARACTERS EACH)

Program a description of each zone. See the keypad programming
insert for entering letters and special characters.

8.54

8.54

8.54

8.54

8.54 BELL SHUT OFF TIME (1-15)

BELL SHUT OFF TIME (1-15)

BELL SHUT OFF TIME (1-15)

BELL SHUT OFF TIME (1-15)

BELL SHUT OFF TIME (1-15)

The length of time (in minutes) the bell will remain on when the
automatic bell shutoff feature is used. The value entered is multiplied
by 2 (maximum time = 30 minutes).

8.55

8.55

8.55

8.55

8.55 AC/LOW BATTERY REPORT DELAY (1-15)

AC/LOW BATTERY REPORT DELAY (1-15)

AC/LOW BATTERY REPORT DELAY (1-15)

AC/LOW BATTERY REPORT DELAY (1-15)

AC/LOW BATTERY REPORT DELAY (1-15)

Time in minutes that a low battery or AC report will be delayed. If the
condition is corrected during the delay time, the report will be
aborted. The audible trouble indication is also delayed by this
amount of time. Unprogrammed value equals zero (0), (maximum
time = 15 minutes).

8.56

8.56

8.56

8.56

8.56 TEST TIMER REPORTING TIME

TEST TIMER REPORTING TIME

TEST TIMER REPORTING TIME

TEST TIMER REPORTING TIME

TEST TIMER REPORTING TIME

Two independent test timers are available and can be programmed to
report the Test Code to any receiver. These timers can be programmed
to report 24 hours from the last report or on a daily, weekly, monthly,
or yearly cycle and at a predetermined time of day. Leave these
locations blank to report 24 hours from the last report. If a predeter-
mined time is desired, set the hour and minute in the same manner as
setting the system time, then set the cycle that the report is to occur.
Programming only the time will result in daily reports. Programming
the day of week will result in the test report being transmitted on that
weekday at the time programmed. Do not program a month or day for
weekly reports. Programming a day of month will result in monthly
reports and programming a month and day of month will yield a yearly
report. Each timer is independent and any combination of report
cycles may be programmed.

8.57

8.57

8.57

8.57

8.57 START TIME FOR OPENING REPORT

START TIME FOR OPENING REPORT

START TIME FOR OPENING REPORT

START TIME FOR OPENING REPORT

START TIME FOR OPENING REPORT
EXCEPTION WINDOW

EXCEPTION WINDOW

EXCEPTION WINDOW

EXCEPTION WINDOW

EXCEPTION WINDOW

Opening/Closing by Exception is a cost saving feature which
reduces the amount of reports. When a Exception Window time is
specified, arming/disarming during this period will not activate a
report; arming/disarming outside this time window will activate an
Opening or Closing report. Even though no Opening/Closing reports
are issued during Exception time, the event is still saved in history.
Enter the time of day that you want to start opening by exception.
Refer to item 59 for the opening time duration.

8.58

8.58

8.58

8.58

8.58 START TIME FOR CLOSING REPORT

START TIME FOR CLOSING REPORT

START TIME FOR CLOSING REPORT

START TIME FOR CLOSING REPORT

START TIME FOR CLOSING REPORT
EXCEPTION WINDOW (

EXCEPTION WINDOW (

EXCEPTION WINDOW (

EXCEPTION WINDOW (

EXCEPTION WINDOW (optional 

optional 

optional 

optional 

optional AUTO-ARM

AUTO-ARM

AUTO-ARM

AUTO-ARM

AUTO-ARM time

 time

 time

 time

 time)))))

Enter the time of day that you want to start the closing by exception
window. Refer to item 59 for closing time duration. (See item 57 for
description and item 61 for examples). Two minutes prior to the
expiration of the closing window, the keypad will annunciate and
display the message:

 .. TIME TO CLOSE .

To extend the closing window by an additional fifteen (15) minutes,
enter the following sequence:

    [PPPP]  [ * ] [ 9 ] [ # ]

Pass Code

Pass Code

Pass Code

Pass Code

Pass Code

This sequence can be repeated fifteen (15) times or accumulated to
12:00 am (midnight), whichever comes first.

This location is where the time is to be pr

This location is where the time is to be pr

This location is where the time is to be pr

This location is where the time is to be pr

This location is where the time is to be programmed at whic

ogrammed at whic

ogrammed at whic

ogrammed at whic

ogrammed at which

h

h

h

h

the A

the A

the A

the A

the Auto-Arm will occur if enab

uto-Arm will occur if enab

uto-Arm will occur if enab

uto-Arm will occur if enab

uto-Arm will occur if enabled in Step 27.

led in Step 27.

led in Step 27.

led in Step 27.

led in Step 27.

8.59

8.59

8.59

8.59

8.59 EXCEPTION WINDOW (1-15)

EXCEPTION WINDOW (1-15)

EXCEPTION WINDOW (1-15)

EXCEPTION WINDOW (1-15)

EXCEPTION WINDOW (1-15)

Enter the time duration desired for the open/closing by exception.
The value entered is multiplied by 15 minutes.  (A range of 15 to 225
minutes is allowed).  Refer to item 61 for examples.

8.60

8.60

8.60

8.60

8.60 EXCEPTION DAYS

EXCEPTION DAYS

EXCEPTION DAYS

EXCEPTION DAYS

EXCEPTION DAYS

An exception day is a day of the week that normal open/closing
reports are not expected (i.e., Saturday and Sunday). If an opening
or closing occurs (no matter what time of day), a report will be
generated. On non exception days (the normal work week - Monday
through Friday), an opening or closing report will only be generated
if the opening or closing occurs outside the designated window.
Enter the days of the week that opening and closing by exception are
not desired. (Sunday = 1  Monday = 2  Saturday = 7).

8.61

8.61

8.61

8.61

8.61 HOLIDAY SCHEDULE

HOLIDAY SCHEDULE

HOLIDAY SCHEDULE

HOLIDAY SCHEDULE

HOLIDAY SCHEDULE

Up to ten holidays may be selected. Holidays used in conjunction
with Opening/Closing by Exception further define the Opening/
Closing schedule. These days are during the week when an Open-
ing/Closing is not anticipated. If the system is opened/closed on a
holiday, the system will report an Opening/Closing report.

Содержание Arrowhead SC1600

Страница 1: ...1600 8 Zone 16 Zone Downloadable Panels Installation Programming Manual Use with EKP1 LED or SK1L LCD keypad Programmed through the LCD keypad or with the ScanPro Downloader Software P N 64812821 A PD...

Страница 2: ...vent History P P P P 1 2 3 2 K eypad A ctivated S witch On P P P P 1 2 4 0 K eypad A ctivated S witch Off P P P P 1 2 4 1 Tim er S witch Toggle P P P P 1 2 4 2 V iew History M ode P P P P 1 2 6 8 E K...

Страница 3: ...cate disable is available Optional Bell shutoff from any partition keypad View History command is available for the User Common E E zones configurable in partitioning Ringback available at the keypad...

Страница 4: ...USER INSTALLER MENUS 13 SECTION 6 PROGRAMMING INSTRUCTIONS 16 SECTION 7 SPECIAL PANEL FEATURES 18 SECTION 8 PROGRAMMING ITEM DESCRIPTION 25 SECTION 9 UL COMPLIANCE 33 SECTION 10 COMPLIANCE 34 SECTION...

Страница 5: ...e NO NO NO NO NOT T T T T usable with this keypad are also indicated on page i SK1L SK1L SK1L SK1L SK1L This is an LCD keypad that can be used in the SC800 and the SC1600 systems It has full full full...

Страница 6: ...E resistors as shown in Figure 1 The SC800 1600 panels can be programmed to not use end of line resistors if required This is done in location 30 section 1 Closed circuit loops are wired in series wit...

Страница 7: ...Figure 1 Figure 1 Figure 1 Battery Connector Modification for large AH Batteries Note The Instructions and drawing shown in Figure 1 below are used when a large AH battery with screw terminals is use...

Страница 8: ...able output has been selected for any function other than burglar operation single bell single bell single bell single bell single bell operation must be selected NO NO NO NO NOTE TE TE TE TE The tot...

Страница 9: ...L TYPICAL TYPICAL TYPICAL TYPICAL TELEPHONE SYSTEM CONNECTION TELEPHONE SYSTEM CONNECTION TELEPHONE SYSTEM CONNECTION TELEPHONE SYSTEM CONNECTION TELEPHONE SYSTEM CONNECTION For proper installation an...

Страница 10: ...e audible warning device will change to a steady sound for 4 seconds in theTEST MODE and then return to a pulsating sound All loops may now be tested independently Violate each loop separately The Arm...

Страница 11: ...d displays system status from one or more locations Additionally built into each keypad is a miniature sounding device which when active indicates various system conditions such as fault test and pre...

Страница 12: ...Group 1 GROUP 2 KEYS PPPP 2 The Group 2 key sequence is used to bypass all burglary zones assigned to Interior Group 2 2 DIGIT KEYS 1 2 The 2 Digit keys are used to enter hexadecimal num bers A F EXA...

Страница 13: ...ory The most recent history event will be displayed immediately Each history event will be displayed in the following format SECTION 5 USER INSTALLER MENUS There are two menus available for the SC sys...

Страница 14: ...ould be inserted into the second slot marked U11 3 Place the installer Pass Code Programming link P1 on the panel to the upper Programming posi tion 4 Power up the panel again 5 Enter the installer me...

Страница 15: ...n a remote PC software on a remote PC software on a remote PC If the P If the P If the P If the P If the Panel P anel P anel P anel P anel Pass ass ass ass assw w w w wor or or or ord f d f d f d f d...

Страница 16: ...NSTR OGRAMMING INSTR OGRAMMING INSTRUCTIONS BE READ UCTIONS BE READ UCTIONS BE READ UCTIONS BE READ UCTIONS BE READ BEFORE A BEFORE A BEFORE A BEFORE A BEFORE ATTEMPTING TTEMPTING TTEMPTING TTEMPTING...

Страница 17: ...press the key so the new data is updated to the permanent EEPROM memory The new phone number is 1 800 777 1313 Pressing the do do do do down arr wn arr wn arr wn arr wn arro o o o ow w w w w or up ar...

Страница 18: ...r alarm technician must be instructed to enter the user menu and select the Ans Ans Ans Ans Answer Call wer Call wer Call wer Call wer Call option once the telephone begins ringing at the premises Aft...

Страница 19: ...ccomplished by setting up a user boundar user boundar user boundar user boundar user boundary y y y y programming an eight 8 in item 67 user attributes for the fir fir fir fir first user of the st use...

Страница 20: ...ime of arming a Force Arm report would be generated The fourth digit in the Close code item 20 is the Force Arm report code and would be transmitted to the central station This code would precede the...

Страница 21: ...AD CODE 2 DIGIT REPORT CODE block of eight zones It is followed by the Zone 16 BYPASS CODE ZONE BLOCK CODE DIGITS ID from Item 25 for zones 9 16 17 TROUBLE CODE ZONE BLOCK CODE DIGITS KEY PAIR 1 3 1 D...

Страница 22: ...6 READY TROUBLE 10 KEYPAD CONTROL SW SELECTION 3 STROBE LIGHT 7 AUDIBLE WARNING 11 P C CONTROL SW 0 FALSE ALARM ZONE 1 ZONE 5 ZONE 9 ZONE 13 34 SHUTDOWN COUNT ZONE 2 ZONE 6 ZONE 10 ZONE 14 1 15 ZONE...

Страница 23: ...TIMER B 57 START OF OPENING EXCEPTION WINDOW HH MM 58 START OF CLOSING EXCEPTION WINDOW HH MM Used as the Arm time for the Auto Arm feature Enable by putting an 8 at Item 27 for Phone 1 59 EXCEPTION...

Страница 24: ...ER 23 USER 9 USER 24 USER 10 USER 25 USER 11 USER 26 USER 12 USER 27 USER 13 USER 28 USER 14 USER 29 USER 15 USER 30 68 ZONES ASSIGNED TO USER SELECT ZONES USER IDENTIFICATION 1 2 3 4 5 6 7 8 9 10 11...

Страница 25: ...e numbers 1 2 and 3 respectfully These account numbers may be three or four digits in length and with a range of 0 9 A F Extended Superfast 4 3 3 SK4 2 and ScanPro Downloader reporting formats require...

Страница 26: ...7 TROUBLE CODE 2 DIGIT HEX TROUBLE CODE 2 DIGIT HEX TROUBLE CODE 2 DIGIT HEX TROUBLE CODE 2 DIGIT HEX TROUBLE CODE 2 DIGIT HEX Code reported whenever a trouble condition is detected First digit used t...

Страница 27: ...on Whatever the digit is programmed for it will be followed by the user 14 14 14 14 14 identifier an E E E E E 4 4 4 4 4 The fourth digit is the Conditional Opening enable Any digit in this position e...

Страница 28: ...hart to set the first system function group 1 No EOL resistor 5 Zones 9 16 installed 2 Secure upload 6 2nd EEPROM INSTALLED 3 Installer privacy code 7 Latched fire bell 4 50 hertz AC 8 Bell shutoff an...

Страница 29: ...it to disable keypad annunciation during exit delay 4 Select this digit to enable the printer DOB DOB DOB DOB DOB module 5 Select this digit to enable the timer output on the system status module or A...

Страница 30: ...8 43 8 43 8 43 ENTRANCE DELAY TIMES 1 15 ENTRANCE DELAY TIMES 1 15 ENTRANCE DELAY TIMES 1 15 ENTRANCE DELAY TIMES 1 15 ENTRANCE DELAY TIMES 1 15 Four 4 entrance delay times are available Each program...

Страница 31: ...be programmed 8 57 8 57 8 57 8 57 8 57 START TIME FOR OPENING REPORT START TIME FOR OPENING REPORT START TIME FOR OPENING REPORT START TIME FOR OPENING REPORT START TIME FOR OPENING REPORT EXCEPTION...

Страница 32: ...unctions for each user Enter function s for each user from the chart below 1 INHIBIT VIEW HISTORY 5 NO EE ZONE DESCRIPTION 2 DOOR STRIKE 6 NO USER PROGRAMMING 3 ARMING ONLY 7 CHANGE OWN CODE ONLY 4 NO...

Страница 33: ...eration must be programmed in order to get a pulsing output for Fire and a constant output on burglary violations Item 33 program anything other than 0 11 Manual shutdown for fire zones Latch Fire Bel...

Страница 34: ...he separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 If necessary the user should consult the a...

Страница 35: ...etiquette cer Cette etiquette cer Cette etiquette cer Cette etiquette certifie que le tifie que le tifie que le tifie que le tifie que le materiel est conf materiel est conf materiel est conf materie...

Страница 36: ...nc sOwners Installation and Programmingmanuals WARRANTY LIMITATION AND EXCLUSION WARRANTY LIMITATION AND EXCLUSION WARRANTY LIMITATION AND EXCLUSION WARRANTY LIMITATION AND EXCLUSION WARRANTY LIMITATI...

Страница 37: ...12 5VDC TOTAL CURRENT NOT TO EXCEED 300mA FOR UL COMMERCIAL AND RESIDENTIAL APPLICATIONS ZONE RESPONSE ZONE RESPONSE ZONE RESPONSE ZONE RESPONSE ZONE RESPONSE TIME TIME TIME TIME TIME PROGRAMMABLE FR...

Страница 38: ...MACHINE BYPASS 18 ANTI JAM 25 ARMED OUTPUT 8 See also WIRING TERMINAL DESCRIPTIONS ARMED OUTPUT ASSIGNABLE OUTPUT 29 See also bell WIRING AUDIBLE WARNING 8 See also WIRING TERMINAL DESCRIPTIONS AUDIB...

Страница 39: ...ION CODE 27 STATUS CODE 27 STATUS MODULE 29 STROBE LIGHT 29 T T T T T TELEPHONE 9 25 TERMINAL DESCRIPTIONS See WIRING TEST CODE 26 TESTING 10 TIMER 29 TEST 31 TONE DIAL 28 TROUBLE 26 U U U U U UPLOAD...

Отзывы: