Page 12 of 15
Doc 6001573
Rev A
Format
Entry code with programmed relay - 13 + entry code (4 digits) + relay
code (1 digit) + #.
Simple
entry
code - 13 + entry code (4 digits) + #.
Relay
1 = Cycle relay 1 for its normal activation time.
Code
2 = Cycle relay 2 for its normal activation time.
3 = Latch relay 1 for an unspecified period of time.
4 = Latch relay 2 for an unspecified period of time.
5 = Release relay 1 from its latched state.
6 = Release relay 2 from its latched state.
7 = Cycle both relays open for their normal activation time.
8 = Latch both relays open.
9 = Release both relays from their latched states.
Example
Entry code with programmed relay - 13 + 5467 + 4 + # (sets up entry
code 5467 to latch relay 2).
Simple entry code - 13 + 3377 + # (sets entry code 3377 to activate relay
1 for its programmed period of time).
Note
You have the capacity to give entry codes to each resident in your
building up to the capacity purchased, plus at least 10 extra for vendors
or service people. Ask your installing dealer for the exact number of
entry
codes
available.
ERASING ENTRY CODE (STEP 14)
Purpose
To delete a 4-digit code that a resident or service person
uses to gain entry to the building without a key.
Format
14 + entry code (4 digits) + #
Example
14 + 5467 + # (deletes entry code 5467).
ERASING ALL ENTRY CODES (STEP 15)
Purpose
To
allow you to clear the entire entry code memory. You would want to
perform this task if the memory has become filled with codes that have
been forgotten or have been entered in error.
Format
15 + #.