Rev A
Doc 6001573
Page 11 of 15
ERASING ALL DIRECTORY CODES
AND TELEPHONE NUMBERS (STEP 11)
Purpose
To Allow you to clear the entire directory code/telephone number
memory. You would want to perform this task if the memory has become
filled with numbers that have been forgotten or have been entered in
error.
Format
11 + #.
SETTING NUMBER OF WRONG ENTRY CODES ALLOWED (STEP 12)
Purpose
To tell the system how many incorrect entry codes may be entered
within a 3 minute period before the system deactivates the entry code
function for a period of 3 minutes. All other functions continue to
operate normally during this time. The number of wrong entries can
be between 0 to 9 incorrect entries. A “0” will disable this feature.
Factory setting = 2 incorrect entries.
Format
12 + number of incorrect entry codes allowed (1 digit) + #.
Example
12 + 6 + # (sets incorrect entry codes allowed at 6).
Note
When an incorrect entry code is entered on the system’s keypad, the
system will respond with an “E” error message on the display. When the
specified number of incorrect entry codes is reached, the system will not
give an error indication on the display. The only indication given by the
system that the incorrect entry code limit has been reached is that the
system will not accept any entry code entries until the 3 minute period is
over.
VERIFYING THE NUMBER
OF INCORRECT ENTRY CODES ALLOWED (STEP 12)
Purpose
To verify the number of incorrect entries that are allowed on the system’s
keypad before the system deactivates the keypad function for 3 minutes.
Format
12 + #.
Notes
Once you press the “#” key, the display will show the number of incorrect
entries allowed. For example, if you have this feature set at 4 entries, the
display will show a “4” after the “#” key is pressed.
PROGRAMMING ENTRY CODES + RELAY ACTION CODE (STEP 13)
Purpose
To Allow you to set up 4-digit codes that residents or service people can
use to gain entry to the building without a key. There are two types of
entry codes that you may enter: entry codes with programmed relays
and “simple” entry codes. Entry codes with programmed relays allows
you to specify which relay the code will activate and how it is activated
when it is entered on the system’s keypad. “Simple” entry codes will only
activate relay 1 for its programmed period of time.