®
Installation Manual
369#
2580
147
CALL
G UP
The Chamberlain Group
845 Larch Ave.
Elmhurst, IL 60125-1196
www.chamberlain.com
Crown Jewel
Telephone entry system
Страница 1: ...llation Manual 3 6 9 2 5 8 0 1 4 7 CALL CALL G UP G UP 3 6 9 2 5 8 0 1 4 7 CALL CALL G UP G UP The Chamberlain Group 845 Larch Ave Elmhurst IL 60125 1196 www chamberlain com Crown Jewel Telephone entry system ...
Страница 2: ...rs 20 Notes 21 22 FCC Requirements 23 DOC Requirements 23 Ground the unit The unit contains parts that may be damaged by static discharge A proper earth ground connected to the lower left grounding screw see page 15 for more information will significantly reduce the chances of damage or improper operation The shielding in the cables specified for all remote sensors and controls should also be conn...
Страница 3: ...lephone wire 18 to 24 AWG twisted pair telephone wire 2 18 to 24 AWG twisted pair telephone wire 18 to 24 AWG twisted pair telephone wire Cabling for Factory Supplied Video Camera Optional Recommendations From a separate power transformer at 120 VAC outlet Shielded Only See Power Wire Table Below Cable Belden 9240 or equivalent BNC Connectors Amphenol 31 1008 or equivalent Between the video output...
Страница 4: ... Side View Surface Mount Dimensions Height Width Depth 5 25 8 75 4 0 Top FLUSH MOUNT Flush Mount Dimensions Height Width Depth 5 0 Back Housing 5 75 Front Panel 8 5 Back Housing 8 75 Front Panel 2 75 Back Housing 5 2 75 1 2 3 4 5 6 7 8 9 0 HANG UP CALL Speaker Keypad 9 72 4 77 3 03 4 35 2 09 6 22 8 5 3 07 2 715 2 715 1 535 3 07 892 892 2 43 2 43 Mounting Holes 4 Wire Knockout Side View Front View ...
Страница 5: ...LL Keypad Speaker Camera Microphone Postal Lock Front View Side View Wire Knockout 5 16 5 16 3 62 1 09 1 09 2 625 2 625 3 07 Mounting Holes 4 3 07 Surface Mount Camera Ready Dimensions Height Width Depth 5 25 10 3 4 0 Top 4 2 81 5 25 Interior View Mounting Hole Positions ...
Страница 6: ...the knock out plug from the back 4 of the housing Secure housing to surface or pedestal post using mounting holes 5 5 Reverse steps 1 4 to reasssemble unit 7 Remove front panel and place on a soft clean surface 4 3 1 1 2 3 4 5 5 4 5 5 Run ALL wires though conduit hole for connections NOTE Knock out holes are for use with 1 2 conduit Keep wires neat Use ties if necesssary 6 Wall Mount Pedestal Moun...
Страница 7: ... R70 4 7K 100 100 GND 1 SEL R90 U23 U20 DS9 LP3 G5V 2 H1 OMRON G5V 2 H1 OMRON G5LE 14 OMRON J2 SPEAKER G5V 2 H1 OMRON C71 C38 C86 DS5 K5 U6 K2 R83 R17 U3 R75 D6 D5 C5 033 IS02 R38 C101 022 DS4 D18 R33 SPEAKER LEVEL J3 D7 D9 D8 SM1110051H CJMB041406002 1 50MKT 47 5 5300060 PT71779 0602 PRC 2 1 3 4 5 7 8 9 6 10 11 12 7 1 DS8 POWER ON LED Indicates the unit has 12 Vac power 2 VR1 SPEAKER LEVEL Used t...
Страница 8: ...eration can be maintained in the event of a malfunction When the unit is in use the bypass switch must be set to the operate position When the unit is disconnected the bypass switch must be set to the bypass position NOTES The voltmeter measurement between the Tip and Ring should be between 48 and 53 Vdc The bypass board located inside the property allows access to the phone in case the unit fails...
Страница 9: ...he bypass boards allow the units to be disconnected without interrupting normal telephone service When the unit is in use the bypass switch must be set to the operate position When the unit is disconnected the bypass switch must be set to the bypass position NOTES The voltmeter measurement between the TIp and Ring should be between 48 and 53 Vdc The bypass board located inside the property allows ...
Страница 10: ...ident s phones EXIT EXIT AUTOCALL TB3 PHONE LINE TB5 COM HOUSE TELCO EARTH GND 7 Circuit Board Use 18 24 AWG 2 twisted pair SINGLE UNIT Ringer Equivalence Number REN 5 Never run data wires and high voltage wires in the same conduit The high voltage wires may interfere with the data wires and cause the system to malfunction MULTIPLE UNITS UP TO 7 Ringer Equivalence Number REN 5 NOTES You must progr...
Страница 11: ...trike 11 BASIC WIRING CONTINUED WIRING A DOOR STRIKE LOCK NORMALLY OPEN RELAY 2 RELAY 1 DS7 RING DS2 11 12 Use 18 24 AWG Circuit Board NOTE Install a 1N4001 diode or equivalent DC Power COM Common NC Normally Closed NOTE Do not use the unit s power supply for the maglock NOTE The maglock can be connected to either of the 2 relays Maglock WIRING A MAGLOCK NORMALLY CLOSED AU TO C A LL E X IT 2 C O M...
Страница 12: ... LINE TB5 TB4 COM PM1 PM2 HOUSE TELCO DS1 EARTH GND 8 COM Common Exit 2 Exit Request Use 18 24 AWG WIRING A KEY SWITCH PIR REX DEVICE Any auxiliary opening device such as a key switch PIR Passive infrared device or an exit request button REX that provides contact closure can be hooked up to the unit TO ACTIVATE RELAY 1 TO ACTIVATE RELAY 2 Connect device to terminals Exit 1 and COM Connect device t...
Страница 13: ...eactivates or is pried open The unit can Call the main residence telephone and report the status of the door Close Relay 2 to activate a device such as a light CCTV camera or siren NOTE You must enable the Alarm Call feature see the Keypad Programming manual for information BASIC WIRING CONTINUED EXIT EXIT AUTOCALL TB3 PHONE LINE TB5 TB4 COM PM1 PM2 HOUSE TELCO DS1 EARTH GND 8 Exit 2 COM Common Us...
Страница 14: ...D SHIELD PIN6 6 ROW1 PIN5 5 COL1 PIN4 4 ROW4 PIN3 3 COL3 PIN2 2 ROW3 PIN1 1 ROW2 Use shielded 7 conductor 18 24 AWG External Keypad WIRING A REMOTE KEYPAD The remote keypad installation requires a shielded 7 conductor 18 24 AWG wire PWR IN RELAY 2 RELAY 1 DS7 TB2 TB1 10 J2 Splice Near Unit Use 18 24 AWG 300 Max Distance Remote Lighted Keypad Circuit Board Power Source WIRING A REMOTE LIGHTED KEYPA...
Страница 15: ...r left hand corner of the circuit board NOTES An earth ground rod is strongly recommended and should be no further than 12 from the unit and use a minimum of 12 gauge wire in most cases The type and length of the earth ground rods vary by region Contact the building inspector s office in the municipality where you plan to install the unit for correct grounding materials and installation procedures...
Страница 16: ...dedicated to the unit only This outlet should be wired back to its own 10 Amp minimum circuit breaker This will prevent two problems 1 Other equipment cannot introduce spikes noise surges or dips into the power circuit 2 The system s operation will not be affected if any other equipment develops a short circuit across the power line Connect the transformer into a 110 Vac outlet after all connectio...
Страница 17: ...hown Verify that Relay 1 activates for the default 10 seconds and that the gate door opens properly It the relay does not activate properly check wiring and retest TEST GATE DOOR RELAYS EXIT EXIT AUTOCALL TB3 PHONE LINE TB5 TB4 COM PM1 PM2 HOUSE TELCO DS1 DS4 SLIC DS3 EARTH GND EXT 8 Jumper Wire EXIT 2 COM RELAY 2 Insert a jumper wire as shown If installed for Control Verify that Relay 2 activates...
Страница 18: ...setting is indicated by a mark on the rim of the FEEDBACK dial VR2 ADJUST AUDIO FEEDBACK 2 If the speaker volume is either too loud or too soft adjust the volume using the Speaker Level VR1 dial 3 When the speaker volume is set to the desired level end the call by hanging up or press 1 Place a call from the unit to the resident s telephone and speak EXIT EXIT AUTOCALL TB3 PHONE LINE TB5 COM HOUSE ...
Страница 19: ...nd make sure a dial tone is emitted from the test set If you do not have access to a telephone test set test the connection using the following procedure 1 Place a telephone call from the resident s telephone to verify it is operating properly then hang up the phone 2 Press the key on the unit s keypad The telephone in the residence should ring 3 Have someone answer the phone and press 9 1 to acti...
Страница 20: ...ghest unit number 1 Press 4 Press 2 Enter Unit ID Code Unit Number 1 7 3 Enter total number of units in chain 2 7 Sets the Unit ID Code as 5 in a chain of 7 units EXAMPLE 1 2 3 4 To Set the Unit ID Number 1 Press 2 Press Verify the Unit Number Adding or removing units will require the Unit IDs to be re entered The Unit ID can ONLY be programmed using the unit s keypad Unit ID Sequencial Order Numb...
Страница 21: ...21 NOTES ...
Страница 22: ...22 NOTES ...
Страница 23: ...ny NOTICE The Canadian Department of Communications label identifies certified equipment This certification means that the equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected...
Страница 24: ...etary to The Chamberlain Group and such information may not be distributed without the prior written consent of The Chamberlain Group The software and firmware included in the Sentex product as they relate to this documentation are also protected by copyright and contain information proprietary to The Chamberlain Group Visit Chamberlain on the web at www chamberlain com For technical support pleas...