background image

Mounting and operating instructions

MTV-1/010-NA

230 VAC POTENTIOMETER

Содержание MTV-1/010-NA

Страница 1: ...Mounting and operating instructions MTV 1 010 NA 230 VAC POTENTIOMETER ...

Страница 2: ...AUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING AND CONNECTIONS 4 MOUNTING INSTRUCTIONS IN STEPS 5 TRANSPORT AND STOCK KEEPING INFORMATION 6 WARRANTY INFORMATION AND RESTRICTIONS 6 MAINTENANCE 7 MTV 1 010 NA 230 VAC POTENTIOMETER ...

Страница 3: ...ble check for condensation spots All installations shall comply with the local health and safety regulations and local electrical codes This product can only be installed by an engineer or a technician who has an expert knowledge of the product and safety precautions Avoid contacts with energised electrical parts always treat the product as if it is life Always disconnect the power source before c...

Страница 4: ...al is required For indoor use only TECHNICAL DATA Power supply 230 VAC 10 50 60 Hz Output 0 10 VDC Load min 1 kΩ Consumption max 8 mA Enclosure External ASA white ivory RAL 9010 IP54 according to EN 60529 Internal polyamide white ivory RAL 9010 IP44 according to IEC 60335 Operating ambient conditions temperature 0 40 C rel humidity 100 rH non condensing Storage temperature 10 55 C STANDARDS Low Vo...

Страница 5: ...the external enclosure 3 Dothewiringaccordingtothewiringdiagram seeFig 1 Wiringandconnections Fig 1 Wiring and connections Power supply Output voltage 4 Mount the internal enclosure into the wall according to the mounting dimensions shown in Fig 2 Mounting dimensions inset mounting Fig 2 Mounting dimensions inset mounting 26 33 50x50 82 89 7 NOTE Mount the unit so that the terminal block and conne...

Страница 6: ... the external one and fix it using the screws and washers included in the set NOTE Mount the unit so that the terminal block and connections are at the lower side 7 Mount back the cover using the nut 8 Put back the knob and turn it to off position 9 Turn on the power supply NOTE A 5 mm hole can be drilled at the bottom of the external enclosure to drain the condensed water TRANSPORT AND STOCK KEEP...

Страница 7: ...s maintenance free If soiled clean with a dry or dampish cloth In case of heavy pollution clean with a non aggressive product In these circumstances the unit should be disconnected from the supply Pay attention that no fluids enter the unit Only reconnect it to the supply when it is completely dry MTV 1 010 NA 230 VAC POTENTIOMETER ...