No. 16S001-ES01
15
STC-CMB401ACXP
Specifications and Users guide
4.2
Saving and Loading a data
This camera can save and load the camera parameters. It is included restoring the factory defaults.
There are two kind of data are exist.
Default: The factory defaults data
UserSet1: User accessible data for saving
The data is loaded and written into in the register on RAM of camera.
These functions can be accessed through the parameters (UserSetSelector, UserSetDefault) and commands
(UserSetLoad, UserSetSave) on UserSetControl category of GenICam
.
For the descriptions of the parameters and commands, please see the table as follow.
GenICam parameters
UserSetSelector
Enumeration
Selects the feature User Set to load from
“Default”, “UserSet1”
UserSetDefault
Enumeration
Selects the feature User Set to load and make active by default
“Default”,” UserSet1” from when the device is reset
UserSetLoad
Command
Loads the User Set specified by UserSetSelector to the device and
makes it active
UserSetSave
Command
Save the User Set specified by UserSetSelector to the non-volatile
memory of the device
4.2.1 Save Setting
Setting Procedure
1. Set UserSet1 on the UserSetSelector
2. Execute UserSetSave
When execute UserSetSave, write the
camera setting information from the
RAM into memory area that was
selected on UserSetSelector.
Note: UserSetSave is not available
when Default on UserSetSelector was
selected
EEPROM
UserSet1 to 8
EEPROM
Default
RAM area
Register
UserSetSelector
Selector