Install

1

Wireless MicroRadar

TM

 Sensor Installation Quick Start Guide:

 

VSN

240

-M

Ensure sensor label is visible 

and record sensor number.

Sensor in Shell

Installation

Core hole 4” diameter,  

2 1/2” depth.

Core

Vacuum or brush hole clear of 

debris.  Ensure hole is dry.

Clear Debris from Hole

Fill EMPTY HOLE half way with 

epoxy.

Apply Epoxy

Ensure sensor is 1/4” or less 

below surface, level, label up, and 

arrow points in direction of traffic. 

Place Sensor

Fill hole with epoxy. Level to 

road surface.

Apply Epoxy

Allow 5 - 10 minutes to cure.

Installed Sensor

Removal, see reverse side

Trim the sensor shell legs to 

level as needed. Ensure that 

the sensor and shell reach the 

required height of 1/4” or less  

below road surface.

Trim Shell Legs

See Important Safety Warnings on  

Opposite Side