Network wiring (Silver/StarNeT 1000)
MPS-4100 product guide • • • 2 - 25
Host or Slave Transmitter
Wire according to the instructions for Relay Output Wiring.
Host Receiver
Use single point grounding for all shields. Ground the shields
to the ground screw on the Receiver housing. Trim and tape the
shields at the other end. Do not allow the individual pair shields
to touch each other or the overall shield.
1. Connect the power wires to TB1.
Observe Polarity
. (See Figure 2-21.)
If the Transmitter tamper is not being connected to the
Receiver, a jumper must be placed across pins 3 & 4 on TB2.
2. Connect the Host Transmitter power and tamper pairs to TB2. Power for the
Slave Receiver also connects to TB2. The tamper input from the Transmitter
must be NC.
3. Install the terminal block and 3 k resistors included in kit E6KT0200 on TB3.
Figure 2-21 MPS-4100 Host Receiver connections
Audio O/P
Tamper O/P
from Transmitter
tape shield
12 to 24 VDC O/P to
Transmitter and Slave Receiver
12 to 24 VDC I/P
from power supply
network connection via
MPS-4100 Communication
Interface Card on PI
Alarm I/P from
Slave Receiver
Tamper I/P from
Slave Receiver
Audio I/P from
Slave Receiver
audio shield
to common
connect return
wires to either
common terminal
Test O/P to
Slave Receiver
S2
1 2 3 4 5 6
JP4
JP6
JP5
JP3
JP1
JP2
S3
TAMPER SW
ALARM
JAM
WRONG
CHANNEL
CH6
CH5
CH4
CH3
CH2
CH1
LOCAL
AUDIO
sensitivity
JP7
3K
no 3K
NC
NO
NC NO
FAST SLOW
TAMPER
ALARM
TAMPER
RV3
ON
OFF
RV2
3K
no 3K
alarm
duration
RV1
MPS-4100
Microwave Receiver
COM
ALM 2
TMPR
TEST 2
COM
AUD 2
TB3
AUD PWR
DATA/
TEST TMP ALM
TB1
+
+
+
XMTTR
CONNECT
TMPR
PWR
TB2
+
P1
S1
1 2 3 4 5 6
ON
OFF
Содержание MPS-4100