![SENSTAR Intelli-FLEX II Скачать руководство пользователя страница 66](http://html.mh-extra.com/html/senstar/intelli-flex-ii/intelli-flex-ii_product-manual_1244251066.webp)
Gate bypass module
5 - 30 • • • Intelli-FLEX II product guide
Single panel swinging gate
Materials required
1 Model 2490-2 Gate bypass module
1 cable splice kit
1 length of non-sensitive feed cable for bypass
Figure 5-30 Single panel swinging gate
Pin #
cable description
Pin #
cable description
1
from annunciator - bypass status - common
7
center conductor of return from gate or
bypassed section
2
from annunciator - bypass status - N/C
8
center conductor to continuing section of
sensor
3
from annunciator - tamper status - common
9
tie point for coax shields
4
from annunciator - tamper status - N/O
(closed when cover is in place)
10
not used
5
from annunciator -+12 VDC
11
center conductor of cable to the gate or
bypassed section
6
from annunciator - ground
12
center conductor from prior section of the
zone
ST
ATUS
COM
TAMPER
N/O
TAMPER
COM
ST
ATUS
N/C
FROM
GA
TE
+12V
GND
SENSOR
OUT
INT
1M
RES
SHIELDS
SENSOR
IN
TO
GA
TE
A
B
C
B
A
C
B
Cable connections
A from prior section of zone
B sensor cable on gate section
C bypass cable from bypass
module to sensor cable
beyond gate
splice kit
pin outs
to
annunciator
to
from
gate bypass module
1
12