Configuration settings
Intelli-FLEX II product guide • • • 7 - 9
Cut Count - Zone 2
To view or change the number of Cuts required to initiate an alarm in Zone 2, set
up the Configuration module so that Zone 2 is selected instead of Zone 1, then
proceed with the instructions for Zone 1.
Climb Window - Zone 1
To view or change the length of time for the Climb Window in Zone 1, proceed as
follows:
1. Connect the Configuration module to the processor.
2. Enter configuration mode by pressing
Mode Select
.
The
Configure
,
Zone 1
,
Cut
and
Time Window
LEDs are lit. The display shows
the number of seconds that the time window is currently set to.
3. Press
Display Select
to sequence the display and LEDs to show
Zone 1
,
Climb
and
Climb Window
.
The display now indicates the number of seconds that the
Zone 2,
Climb
Window
will remain active once it is activated.
If your intent was to view the parameter you are finished. To change the
parameter, continue.
4. Use
Increase
or
Decrease
as necessary to change the value for the
Zone 1,
Climb,
Climb Window
.
•
Pressing
Increase
will increase the parameter value by one unit each time
the key is pressed.
•
Pressing
Decrease
will decrease the parameter value by one unit each
time the key is pressed.
5. When the desired value is displayed, press
Load
.
Load must be pressed immediately after Increase or
Decrease for the new value to the saved, otherwise the
original value will be retained.
Climb Window - Zone 2
To view or change the length of time for the Climb Window in Zone 2, set up the
Configuration module so that Zone 2 is selected instead of Zone 1, then proceed
with the instructions for Zone 1.