Installing the FlexZone processor
Page 52
FlexZone Product Guide
Cable entry ports
The bottom of the FlexZone enclosure includes five cable entry ports fitted with compression
glands for the sensor cables, power cable, and alarm data cables. The central port includes a
12.7 mm (1/2 in.) cable gland, which fits cables ranging between 4.3 - 11.4 mm (0.17 to 0.45 in.).
The other four ports (two on each side) provide 9.5 mm (3/8 in.) compression glands, which fit
cables ranging between 2.9 - 7.9 mm (0.115 to 0.312 in.). Five weatherproof plugs are included for
instances where not all of the cable entry ports are required. The bottom of the enclosure also
includes an exterior ground lug for the earth ground connection.
If FlexZone armored cable is being connected to the processor, the two sensor cable ports must
be drilled out and fitted with 1/2 in. cable glands (included with armored shell; see
armored sensor cable to the processor on page 50
Item Description
Item Description
1
Network interface card mounting hardware (X 2) 9
T8 - Form C relay output connections (X4)
Normally Closed, Common, Normally Open
2
Activity LEDs - DOOR OPEN, UCM ACTIVE,
NETWORK POWER FAIL, INTERNAL POWER
FAIL, FPGA ACTIVITY, BOOT FAIL, MEMORY
FAIL, HEARTBEAT, TXA, RXA, FAULT A, TXB,
RXB, FAULT B (LED ON = condition active)
10
T9 (terminals 1, 2, 3) - A Side sensor cable input
(1 & 3 = shield, 2 = center conductor)
11
T9 (terminals 4, 5, 6) - B Side sensor cable input
(4 & 6 = shield, 5 = center conductor)
3
T1 - tamper input
12
T4 - power input (- +) 12 to 48 VDC
4
SD Active LED
13
T7 - Auxiliary inputs (self-test/auxiliary device
inputs) AUX 1 - +, AUX 2 - +
5
SD record button (ON/OFF)
14
Relay activity LEDs (X4) - LED ON = relay active
6
microSD card slot
15
Tamper switch - open = tamper alarm
7
T3 - USB connection to UCM PC
16
T2 - Expansion header for network interface card,
gate sensor receiver and I/O card
8
UCM activity LEDs (TX, RX)
Table 1 Processor features
Figure 61: Cable entry recommendations
sensor cable Side B
sensor cable Side A
network communications
relay outputs
12 to 48 VDC
auxiliary inputs/self-test
earth ground