page 42 008-0608-01
3.6.7
DIAG
DIAG
DIAG
DIAGNNNNOSTICS
OSTICS
OSTICS
OSTICS
Sub-Menu
DDDDAAAACCCC FFFFUUUULLLLL S
L S
L S
L SCCCCAAAALLLLEEEE
Menu Item
When this menu item is selected, the Analog Output of the channel is forced to its full-
scale output, then
DDDDAAAACCCC UUUUPPPPDDDDAAAATTTTEEEEDDDD
is displayed. This is useful when calibrating or trimming
the readout connected to the Analog Output.
DDDDAAAACCCC ZZZZEEEERRRRO S
O S
O S
O SCCCCAAAALLLLEEEE
Menu Item
When this menu item is selected, the Analog Output of the channel is forced to its
zero-scale output, then
DDDDAAAAC UP
C UP
C UP
C UPDDDDAAAATTTTEEEEDDDD
is displayed. This is useful when calibrating or trim-
ming the readout connected to the Analog Output.
VVVVEEEERRRRSSSSIIIIOOOONNNN INF
INF
INF
INFOOOO
Menu Item
This menu item displays the part number and revision level of the firmware used by
this channels microprocessor.
DDDDIIIISSSSPPPPLLLLAAAAYYYY AD
AD
AD
ADCCCC
Menu Item
The options for this menu item are:
•
“
OOOOFFFFFFFF
” will allow the [VALUE] button to cycle through “
TTTTKKKK
” (tracking value), “
HHHHIIII
” (peak
value) and “
LLLLOOOO
” (valley value). This is the recommended option.
•
“
OOOONNNN
” will allow the “
AAAADDDD
” (percentage of the Analog-to-Digital converter’s full-scale
digitizing capability) display source to be available along with “
TTTTKKKK
” (tracking value),
“
HHHHIIII
” (peak value) and “
LLLLOOOO
” (valley value) when the [VALUE] button is pressed on
the front panel.
The Analog-to-Digital converter counts are displayed as a percentage from -100.00%
to 100.00%.
This can be used to verify the correct operation of the input circuitry of the channel.
LLLLIIIINNNNEEEEAAAARRRRIIIIZZZZAAAATTTTIIIION
ON
ON
ON
Menu Item
The options for this menu item are:
•
“
OOOONNNN
” will allow the linearization data obtained from the 5-Point Known Load Cali-
bration to affect a channel’s scaled values. This is the recommended option.
•
“
OOOOFFFFFFFF
” will not allow linearization data to effect the channel’s scaled values. This is
useful when diagnosing problems in a calibration procedure.
DDDDIIIISSSSAAAABBBBLLLLEEEE CCCCHHHHAAAANNNNNNNNEEEELLLL
Menu
Item
The options for this menu item are:
•
“
OOOONNNN
” will bypass the INITIALIZE and RUN modes of the channel. The track, peak
and valley values of the channel are forced to 0. This option is helpful when a
channel is installed but not being used.
•
“
OOOOFFFFFFFF
” will allow normal operation of the channel.
Содержание SC1000
Страница 7: ...Additional Channels for SC Series Instrumentation page 7 INTRODUCTION 1 ...
Страница 8: ...page 8 008 0608 01 ...
Страница 31: ...Additional Channels for SC Series Instrumentation page 31 RTD INPUT CHANNEL 2 ...
Страница 32: ...page 32 008 0608 01 ...
Страница 53: ...Additional Channels for SC Series Instrumentation page 53 FREQUENCY INPUT CHANNEL 3 ...
Страница 54: ...page 54 008 0608 01 ...
Страница 58: ...page 58 008 0608 01 ...
Страница 60: ...page 60 008 0608 01 ...