Sensopart 529-11008 Скачать руководство пользователя страница 1

RailPilot – optical anti-collision sensors

System manual FR 85-2 ILLG-POL5 | FR 85-2 ILLG-S1L5

Optical sensors

 

Ultrasonic sensors 

Inductive sensors 

 

Vision sensors and systems

Содержание 529-11008

Страница 1: ...RailPilot optical anti collision sensors System manual FR 85 2 ILLG POL5 FR 85 2 ILLG S1L5 Optical sensors Ultrasonic sensors Inductive sensors Vision sensors and systems...

Страница 2: ...RailPilot system manual 1...

Страница 3: ...l systems or data bases in any manner whatsoever nor may illustrations drawings and the layout be copied without prior written permission from SensoPart Industriesensorik GmbH We accept no responsibil...

Страница 4: ...fety ranges 9 1 4 Installation Mounting suggestion 9 2 Setting FR 85 with PC software 10 2 1 Serial communication FR 85 2 ILLG S1L5 10 2 2 PC Software FR85 2 ILLG protocol tester 11 2 3 FR 85 2 ILLG P...

Страница 5: ...e switching points regardless of the surroundings and conditions of the vehicles themselves a reflector is fitted to the rear of every vehicle present in the installation RailPilot is fitted to the fr...

Страница 6: ...e principle of pulsed time of flight measurement With pulsed time of flight measurement a very short light impulse is emitted reflected and registered by the receiver measured time is stopped at that...

Страница 7: ...virtually identical as each version only detects reflectors within its detection range Machines or rail components which may also be in the field of vision do not affect the RailPilot Close up at dist...

Страница 8: ...itioning vehicles carrying greatly overhanging loads The vehicles can thus travel close up when unloaded but keep to a greater distance when loaded Both signal outputs are N C so that there is protect...

Страница 9: ...for the distance to the reflector in front If the reflector is within detection range RailPilot sends the distance value to the control system otherwise the signal sent indicates no reflector detected...

Страница 10: ...ween close far safety ranges Schematic diagram of change over using bi stable magnetic switches 1 4 Installation Mounting suggestion The illustrated frame protection prevents damage occurring to senso...

Страница 11: ...sensor suitable for immediate use with the DETO control system When used with the LJU control system the baudrate must be set to 62 5 kBaud see transmission protocol data sheet and description of tes...

Страница 12: ...has been switched on the sensor monitors its RS485 interface with a baudrate of 57 6 kBaud for 100 ms and tries to receive the command C If the command C is received within 100 ms the sensor knows th...

Страница 13: ...tomatic setting of baudrate for LJU control systems FR 85 2 ILLG S1L5 Displays the last strings sent by FR 85 ILLG S1L5 in bytes in dec and hex Automatic setting of baudrate for DETO control systems F...

Страница 14: ...ssumes no responsibility for damage which may occur when installing or operating the ProgSensor programme 2 4 2 Installation In order to use ProgSensor software it must be installed under Windows Inst...

Страница 15: ...the program Sensor Select the connected sensor type The choice ist between automatic or manual Sensor data Read current sensor settings send settings from software to FR 85 2 ILLG Start online mode of...

Страница 16: ...g from sensor 4 Disconnect sensor that has been read and connect sensor to be programmed in its place 5 Transfer parameters to sensor Steps 4 and 5 can be repeated as many times as required without re...

Страница 17: ...r sensors Miniature sensors Distance sensors Color sensors Contrast sensors Anti collision sensors Slot sensors Fiber optic sensors Inductive sensors Ultrasonic sensors Vision sensors Smart cameras Vi...