SENSIRION Nubo Sphere Скачать руководство пользователя страница 1

 

 

 

 

 

User Manual for  
 

Nubo Sphere  
Sensor Node (LTE MOx) & Wind Meter 

Continuous  Methane  Leakage  Monitoring 
System 

 

Revision 0.2 from June 1, 2022 

 

Nubo Sphere  

User Manual 

Содержание Nubo Sphere

Страница 1: ...User Manual for Nubo Sphere Sensor Node LTE MOx Wind Meter Continuous Methane Leakage Monitoring System Revision 0 2 from June 1 2022 Nubo Sphere User Manual ...

Страница 2: ...king with the device to avoid damage to the device or injury Please read the manual carefully and follow the procedures of operation as prescribed Caution Caution means that incorrect use might break the device Failure to follow the procedures explained and prescribed in this manual might result in irreversible damage to the device Warning Warning means that unsafe use of the device can result in ...

Страница 3: ... pole mounts 9 3 2 3 Node without wind meter 10 3 2 4 Node with wind meter 12 3 3 Registering device to cloud 14 3 4 Before leaving the site 15 4 Maintenance 15 4 1 General 15 4 2 Cartridge replacement 15 5 General handling 16 5 1 Powering up the device 16 5 2 Depowering the device 16 5 3 Storage 16 5 4 Shipment 17 6 Conformity information 18 6 1 European conformity information 18 6 2 FCC notice 1...

Страница 4: ... maintenance expenses and provide a future proof sustainable setup Nubo Sphere changes the state of the art in methane emissions monitoring Detecting locating and quantifying fugitive methane emissions have never been easier The deployment of consistent ground based methane data logging enables emission detection much earlier than was previously possible through human detection ensuring fast accur...

Страница 5: ...n at any time The nodes transmit the data constantly to the cloud platform via LTE M or 2G GPRS Every node has its own connectivity to ensure maximum redundancy simple and rapid setup and flexibility At the cloud level the signals are refined to exclude artifacts and ensure maximal data fidelity The algorithms have been developed on the basis of Sensirion s extensive know how with the employed sen...

Страница 6: ...ting adapter 4 1 pole mount 5 2 band ties for the pole mount 6 For a typical installation multiple sensor nodes 4 to 12 depending on conditions and goals for a 150 x 150 m2 500 x 500 ft 2 site and at least one wind meter are required The exact numbers depend on the specifics of the installation site e g the size the installed equipment and the performance requirements For additional details please...

Страница 7: ...ot install in rainy conditions The device is to be operated with the supplied powering options only Do not attach any other power supplies Do not use the supplied powering options for any purpose other than powering the device The device contains a lithium ion battery Do not store or operate the device or battery in temperature conditions outside the specified range Do not crush the device or its ...

Страница 8: ...All elements of the system must not be placed within hazardous zones Nubo Sphere sensor nodes should be placed approximately 20 to 60 m 66 to 197 ft downwind of potential emission sources The units can be installed either on new poles or on existing infrastructure In the latter case ensure that no other equipment that might influence the wind patterns is in close proximity to the units especially ...

Страница 9: ...aces can have sharp edges Wear protective gloves and smooth out the edge with a file Warning Using the pole mount adapters may result in scratch marks or abrasion on the chosen pole By installing and using this mounting kit you accept that Sensirion Connected Solutions AG is not liable for any damage resulting from the installation and use of the pole mount adapters Plastic zip ties might age and ...

Страница 10: ... and the solar panel by sliding the corresponding backplate into the mounting plate 3 Mount the sensor node to the lower plate and the solar panel to the upper plate 4 For ease of installation the mounts are designed so that the node and the accessories remain in place without the screws being tightened However it is important to tighten both screws on each side of every mount to ensure safe and s...

Страница 11: ...fy whether installation of the device is permissible by local laws and or by the owner of the infrastructure It is the responsibility of the person installing the device to ensure secure and safe installation Sensirion Connected Solutions AG cannot be held liable for damages and or injuries due to improper placement or installation Do not install and or operate the device or any accessories withou...

Страница 12: ...ackplate into the mounting plate 3 Mount the sensor node to the bottom plate the solar panel to the middle plate and the wind meter arm to the upper plate 4 For ease of installation the mounts are designed so that the node and the accessories remain in place without the screws being tightened However it is important to tighten the screws on the side to ensure safe and secure fixation of the system...

Страница 13: ... sequence It will then perform a self test and establish communication with the cloud During this time the LED will blink orange Once the device is correctly working the LED will turn solid green for as long as 1 min Afterwards it turns off to save power If any error occurs the LED will flash red Warning It is in your responsibility to verify whether installation of the device is permissible by lo...

Страница 14: ...our smartphone to register devices directly in the field To register a device in the field with a smartphone simply 1 Go to https cloud nubo sphere com 2 Login in using your personal credentials 3 Select New device registration from the menu 4 In case your smartphone asks you please allow use of your camera you can select Remember decision for this site to avoid this question next time 5 Verify or...

Страница 15: ...lean and dry Loosen all four cartridge screws before attempting to remove the cartridge Afterwards grab the external parts of the cartridge and pull the cartridge in the direction opposite the direction of installation Insert the replacement cartridge into the now empty slot Insert the cartridge until you hear and feel it snap into place Fix the cartridge inside the device by tightening the integr...

Страница 16: ...connect the battery for transport After the device has been depowered be certain to correctly install the protective cap to protect the pin s connector and avoid corrosion or dirt build up 5 3 Storage The system operates whenever a power plug is connected Please always disconnect the cable of the power source from the device as described in section 5 2 when storing it This procedure ensures that t...

Страница 17: ... a large buffer battery and will continue to run unless the device side connector of the power cord is disconnected Before transporting or shipping the device powering down the device as described in section 5 2 is critical The device contains batteries please ensure correct handling and labelling when shipping the device Warning The device contains batteries Store the device within the specified ...

Страница 18: ...les These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions can cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installat...

Страница 19: ...mum output power 33 dBm rated GSM 1800 Operating frequency range 1710 1785 1805 1880 MHz Maximum output power 30 dBm rated LTE FDD Band 1 Operating frequency range 1920 1980 2110 2170 MHz Maximum output power 23 dBm rated LTE FDD Band 3 Operating frequency range 1710 1785 1805 1880 MHz Maximum output power 23 dBm rated LTE FDD Band 8 Operating frequency range 880 915 925 960 MHz Maximum output pow...

Страница 20: ...atisfaction to have arisen from SCS faulty design material or workmanship the defective product is returned to SCS factory at the Buyer s expense and the warranty period for any repaired or replaced product is limited to the unexpired portion of the original period This warranty does not apply to any equipment that has not been installed and used within the specifications recommended by SCS for th...

Страница 21: ...Solutions AG Laubisrütistr 50 CH 8712 Stäfa ZH Switzerland phone 41 44 306 40 00 fax 41 44 306 40 30 info sensirion com sensirion connected com Sensirion Connected Solutions Inc USA Sensirion Connected Solutions Inc 11 East Adams Suite 220 Chicago IL 60603 phone 1 312 690 5858 info sensirion com sensirion connected com AiSight GmbH Gertraudenstrasse 10 12 10178 Berlin Germany phone 49 30 403 633 9...