Minnow 1.0T & Minnow 1.0TH
User Guide
Senonics LLC
www.senonics.com [email protected] [email protected]
Revision 1.0.4
Senonics LLC ©
8/11
4.5.
Cloning Loggers
For customers that expect to configure multiple loggers
with the same configuration, Senonics offer the clone
feature.
First, press the clone icon
or navigate
File>Clone Logger
.
You are then presented with two copies of the
configuration pane. Enter your configuration in the left-
most pane. When you are complete press the "Clone
Settings" button. This will copy all settings across to the
right-most pane. When you are satisfied press the "Lock
Settings" tick-box.
You can then connect loggers to your PC. When you
press "
Configure” the new logger is programmed each
time with the same cloned settings.
Be aware that the Device ID is not cloned, in order to
preserve the logger identification. At any time, you can
unlock, change settings and then lock again.
Figure 7: Logger Cloning
Distributed by MicroDAQ.com, Ltd. www.MicroDAQ.com (603) 746-5524