background image

Important safety instructions

2 | RS  5200

Important safety instructions

Read this instruction manual carefully and completely 
before using the product.

Always include this instruction manual when passing the 
product on to third parties.

Do not use an obviously defective product. 

Only use the product in environments where wireless 2.4 GHz 
transmission is permitted.

Preventing damage to health and accidents

These headphones allow you to set higher volumes than 
conventional headphones. Protect your hearing from high 
volume levels. 
Permanent hearing damage may occur when headphones are 
used at high volume levels for long periods of time. Sennheiser 
headphones sound exceptionally good and provide clear speech 
intelligibility at low and medium volume levels.

To prevent hearing damage, set the volume to a low level before 
passing the product on to third parties.

Do not use the product in an environment that requires your spe-
cial attention (e.g. in traffic or when performing skilled jobs).

Always keep the headphones/MCA 800 charging 
adapter at least 3.94" (10 cm) from cardiac pacemakers, 
implanted defibrillators (ICDs) and other implants. The 
headphones/MCA 800 charging adapter generate/s magnetic 
fields that could cause interference with cardiac pacemakers, 
implanted defibrillators (ICDs) and other implants.

Do not use the product near water. To reduce the risk of fire or 
electric shock, do not expose the product to rain or moisture.

Keep the product, accessories and packaging parts out of reach 
of children and pets to prevent accidents. Swallowing and chok-
ing hazard.

Only use the power supply units supplied by Sennheiser.

Preventing damage to the product and malfunctions

Always keep the product dry and do not expose it to extreme tem-
peratures (hairdryer, heater, extended exposure to sunlight, etc.) 
to avoid corrosion or deformation. The normal operating tempera-
ture is from 5 °C to 40 °C/32 °F to 104 °F.

Use the product with care and store it in a clean, dust-free envi-
ronment.

Switch off the product after use to conserve battery power.

Unplug the power supply unit from the wall socket

– to completely disconnect the product from the power source,

– during lightning storms or

– when not using the product for long periods of time.

Always ensure that the power supply unit is 

– in a safe operating condition and easily accessible,

– properly plugged into the wall socket,

– only operated within the permissible temperature range,

– not exposed to direct sunlight for longer periods of time in order

to prevent heat accumulation.

Содержание TR 5000

Страница 1: ...nction the navigation left or the following links Start Product overview Putting the RS 5200 into operation Using the RS 5200 Using the RS 5200 s additional functions If a problem occurs Specifications Sennheiser electronic GmbH Co KG Am Labor 1 30900 Wedemark Germany www sennheiser com Version 06 21 A01 ...

Страница 2: ...800 charging adapter generate s magnetic fields that could cause interference with cardiac pacemakers implanted defibrillators ICDs and other implants Do not use the product near water To reduce the risk of fire or electric shock do not expose the product to rain or moisture Keep the product accessories and packaging parts out of reach of children and pets to prevent accidents Swallowing and chok ...

Страница 3: ...If abused or misused rechargeable batteries may leak In extreme cases they may even present a risk of explosion heat and fire development smoke and or gas development damage to health and or the environment Only use rechargeable batteries and chargers recom mended by Sennheiser Do not charge a product with a built in rechargeable battery if the product is obviously defective Only charge the produc...

Страница 4: ...ny appli cation not named in the corresponding product documentation Sennheiser does not accept liability for damage arising from misuse or improper use of this product and its attachments accessories Before putting the product into operation please observe the respective country specific regulations ...

Страница 5: ... 1 pair of memory foam ear pads 1 pair of open foam ear pads Optical digital cable 1 5 m Stereo audio cable with 3 5 mm jack plugs 1 5 m RCA adapter 3 5 mm jack socket to 2 RCA connec tors Safety guide Quick guide Instruction manual in English German French and Spanish The instruction manual in other languages can be downloaded at www sennheiser com download Safety Guide Quick Guide Instruction Ma...

Страница 6: ...er Model RR 5200 Ear pads replaceable Ear bows with on off function Volume buttons and Receiver status LED see page 8 Speech intelligibility button R marking for the right ear and L marking for the left ear Built in rechargeable battery Charging contacts 2 6 1 3 7 8 4 5 On Off ...

Страница 7: ...Hearing profile LED indicating the activated hearing profile see page 23 Charging compartment for stethoset receiver Charging contacts for stethoset receiver with holding mag nets Transmitter status LED see page 8 Digital Optical In audio input marked pink for connecting a digital audio source optical 5V DC 1A socket marked yellow for connecting the power supply unit Analog 3 5 mm In audio input m...

Страница 8: ...cannot connect to the transmitter flashes red is not connected to the transmitter or cannot connect to the transmitter the rechargeable battery is almost empty 1s 1s 1s 1s Transmitter status LED The transmitter is in standby mode lights up white and the stethoset receiver are connected The speech intelligibility function is deactivated see page 26 lights up blue and the stethoset receiver are conn...

Страница 9: ...m after approx 30 seconds to not disturb you Beeps Meaning during operation 2 beeps The rechargeable battery is almost empty recharge the rechargeable battery see page 15 during operation no audio transmission 5 beeps The receiver is outside the transmission range see page 39 when changing the volume The maximum or minimum volume is reached see page 22 when changing the balance setting The maximum...

Страница 10: ...rce e g a TV and a stereo hi fi system If you connect an audio source to both inputs digital and analog only the analog audio source will be reproduced Switch your audio source off before connecting the transmitter Check the connection possibilities of your audio source audio output usually marked OUT Select the corresponding connection cable and if necessary a suitable adapter To connect the tran...

Страница 11: ...ce you are using Connect the optical digital cable to the pink Digital Optical In audio input of the transmitter and to the optical output of your audio source Connection possibilities of the audio source Colorcoding on the transmitter Connection cable Page Optical digital Optical digital cable 11 3 5 mm jack socket analog Stereo audio cable 13 RCA analog Stereo audio cable with RCA adapter 3 5 mm...

Страница 12: ...Putting the RS 5200 into operation 12 RS 5200 Digital Audio 1A OPTICAL OUT ...

Страница 13: ...me TV models mute the loudspeakers when you connect the transmitter to the 3 5 mm headphone socket Other TV models have their own menu for adjusting the volume of the headphone socket Check the menu of your TV for information on how to deactivate the muting function or adjust the volume Alternatively connect the TV and the transmitter using a different connection possibility A C or D B Adjust the ...

Страница 14: ...eled AUDIO OUT or of your audio source Connect the red con nector to the red RCA socket and the white connector to the white or black RCA socket Connection possibility D SCART socket analog Plug the SCART adapter onto the stereo audio cable Connect the stereo audio cable to the blue 3 5 mm jack socket of the transmitter Connect the SCART connector to the SCART socket mostly labeled or of your audi...

Страница 15: ...its rechargeable battery for a com plete charging cycle without interruption When the rechargeable battery is almost empty the Receiver status LED lights up red and you hear 2 beeps in the stethoset receiver The Battery LED on the transmitter flashes white The stethoset receiver switches off after a few minutes Place the stethoset receiver into the transmitter s charging com partment so that the v...

Страница 16: ...geable battery is being charged Up to 1 3 of the charge capacity is reached 1st 2nd LED segments lit 3rd LED segment flashes The rechargeable battery is being charged Up to 2 3 of the charge capacity is reached All LED segments lit The rechargeable battery is fully charged Battery LED flashes rapidly A charging error battery error has occurred see page 29 Always store the stethoset receiver in the...

Страница 17: ...e ste thoset receiver Charge the stethoset receiver by placing it into the transmitter s charging compartment see page 15 The LED stops flashing and the charging process starts Battery LED Meaning Battery LED flashes slowly Rechargeable battery is empty recharge the rechargeable battery 1st LED segment lit approx 4 hours of operating time 1st 2nd LED segment lit approx 8 hours of operating time Al...

Страница 18: ...oise attenuating fit of the receiver in the ears With intensive use the memory effect of the foam wears off after a few months causing the pressure relief to deteriorate In this case replace the ear pads with new ones Ear pads made of open foam for pressure sensitive ears and a lightweight wearing comfort even over long periods of use Due to the open foam the hygienic durability is limited Clean t...

Страница 19: ...Putting the RS 5200 into operation RS 5200 19 Spare ear pads in different materials and forms are available from your Sennheiser partner 2 1 ...

Страница 20: ...Receiver status LED lights up green The transmitter automatically switches on and the Transmitter status LED lights up white or blue The audio transmission starts The remaining operating time of the stethoset receiver is dis played on the transmitter see page 16 WARNING Danger of hearing damage due to high volumes This receiver allows you to set higher volumes than conventional devices Constant hi...

Страница 21: ...t hangs freely from your ears and rests lightly on your chest When putting the stethoset receiver on observe the L left and R right markings on the rear of the ear bows The volume buttons face away from your body to facilitate ease of use Wear the stethoset receiver so that the ear pads are positioned just in front of your ear canals you feel a gentle pressure on your ears The ear pads adapt to yo...

Страница 22: ...r left right volume adjustment Adjust the balance so that you hear equally well with both ears WARNING Danger of hearing damage due to high volume levels Before putting the stethoset receiver on set the volume on the receiver to a low level Do not expose yourself to high volume levels for extended periods of time If you have set a very high volume level and switch the TV head phone system off and ...

Страница 23: ...io signal in order to especially improve the speech intelligibility The profiles are used to specifically change certain frequency ranges by e g boosting or attenuating low frequency or high frequency tones The balance setting is stored on the stethoset receiver If you are using several receivers with a transmitter the respective receivers are optimally adjusted to match the personal hearing prefe...

Страница 24: ... receivers are optimally adjusted to match the personal hearing preferences of the users e g you and your partner Please note that the personal hearing preferences can only be adjusted when only stethoset receiver is connected to the transmitter 2s Activated hearing profile Hearing profile LED Sound enhancement Compression No LED segment lit The sound from the connected audio source is reproduced ...

Страница 25: ...he balance see page 22 This ensures that each subsequently selected hearing profile is perfectly matched to your left right balance set ting 4 Press the Hearing profile button on the transmitter for 2 seconds to select the next hearing profile Press the button again for 2 seconds to switch to the next hearing profile 5 Test which of the hearing profiles 1 2 or 3 gives you the best sound quality an...

Страница 26: ...e we recommend that you repeat the selection of the hearing profile from time to time If you switch to the next hearing profile the speech intelligibil ity function is automatically deactivated so that you can hear the hearing profile unchanged see page 26 To prevent accidental adjustment of the hearing profile set tings you can activate the hearing profile protection see page 33 Application Speec...

Страница 27: ...gibility function lights up blue activated Annoying background noise is effectively reduced speech becomes clearer and easier to understand lights up white deactivated The speech intelligibility function can also be used in addition to one of the hearing profiles 1 3 ...

Страница 28: ...ds Reach behind the ear pads with your fingernails so that you can carefully detach the ear pads from the stethoset receiver Clean the ear pads under lukewarm running water Let the ear pads air dry at room temperature for at least 12 hours before using them again Put the ear pads back on the stethoset receiver The rubber ring of the ear pads locks into place on the stethoset receiver CAUTION Liqui...

Страница 29: ...ce partner You need suitable tools for replacement We therefore recommend to have the rechargeable battery replaced by your Sennheiser service partner To find a Sennheiser partner in your country search at www sennheiser com service support For reasons of hygiene the ear pads should be replaced from time to time especially the ear pads made of memory foam and open foam only have a durability of a ...

Страница 30: ...switched on receivers cannot connect to the transmitter Option A contact pairing Place the stethoset receiver into the transmitter s charging com partment The stethoset receiver is paired with the transmitter Option B proximity pairing 1 Place the stethoset receiver as close as possible to the transmit ter 2 Switch the stethoset receiver on by pulling the ear bows apart 3 Simultaneously press and ...

Страница 31: ...essed and connect the trans mitter to the power supply system by connecting the connector of the power supply unit to the yellow socket of the transmitter The protected settings mode is activated The Transmitter status LED flashes blue The LED segments indicate the current settings as specified in the following chapters battery status display see page 32 charging reminder function see page 32 hear...

Страница 32: ... using To activate or deactivate the function Make sure that the protected settings mode is activated see page 31 Press the Balance button R on the transmitter Status and display of the Battery LED Function behavior permanently activated operation and charging 1st LED segment lit The current charge status is permanently displayed during charging The remaining charge status is permanently displayed...

Страница 33: ...he protected settings mode is activated see page 31 Place the stethoset receiver into the transmitter s charging com partment Press the volume button on the stethoset receiver to activate or deactivate the hearing profile and balance protection Status and display of the charging reminder function Function behavior activated 3rd LED segment lit When you switch the stethoset receiver off and the tra...

Страница 34: ...t least 3 seconds All LEDs on the transmitter flash The transmitter settings are restored to the factory settings To restore a stethoset receiver to the factory settings Status and display of the protection function Function behavior activated 2nd LED segment lit The activated hearing profile and the balance setting cannot be changed deactivated deactivated 2nd LED segment off The hearing profiles...

Страница 35: ...adapter If you have purchased an additional stethoset receiver or an optional MCA 800 charging adapter you can also charge the stethoset receiver using the charging adapter Always keep the headphones MCA 800 charging adapter at least 3 94 10 cm from cardiac pacemakers implanted defibrillators ICDs and other implants The headphones MCA 800 charging adapter generate s magnetic fields that could caus...

Страница 36: ...adapter flashes red and green a charging error battery error has occurred In this case disconnect the charging adapter from the stethoset receiver For additional informa tion on the rechargeable battery see page 29 WARNING Interference due to magnetic fields The MCA 800 charging adapter generates stronger permanent mag netic fields that could cause interference with cardiac pacemakers implanted de...

Страница 37: ...onal stethoset receiver receiver Pair the stethoset receiver with the transmitter again 30 No audio signal when a digital audio source is connected Cables are connected to both the digital and the analog audio input Remove the cable from the analog audio input 10 The connected digital audio source uses an incompatible audio format The Transmitter status LED flashes white and blue Set the audio for...

Страница 38: ...ory foam or silicone 18 The battery status display goes off The battery status display is set so that it goes off after 30 seconds Set the battery status display so that it is permanently displayed 32 More than one stethoset receiver is currently connected to the trans mitter This function is only possible when only one stethoset receiver receiver is connected to the transmitter 2 beeps during ope...

Страница 39: ...udio drops out occasionally at first before the connection breaks down completely You hear alerts in the stethoset receiver and the Receiver status LED flashes green or red if the rechargeable battery is almost empty If you re enter the transmission range within 5 minutes the connec tion is automatically re established If you spend more than 5 minutes outside the transmission range the stethoset r...

Страница 40: ...umidity non condensing operation 10 to 80 storage 10 to 90 Type intra aural closed Transducer principle dynamic neodymium magnets Ear pad material silicone silicone elastomer memory foam PUR open foam PUR Frequency response 15 Hz to 16 kHz Sound pressure level max 125 dB at 1 kHz 3 THD THD 0 5 at 1 kHz 100 dB SPL Operating time up to 12 hours Charging time of recharge able battery up to 3 hours Po...

Страница 41: ...nsumption operation typ 1 W standby 0 5 W without charging Dimensions W x H x D approx 50 mm x 42 mm x 270 mm Nominal input voltage cur rent 100 240 V 300 mA Power frequency 50 60 Hz Nominal output voltage 5 V Nominal output current 1 A Temperature range operation 0 C to 40 C storage 25 C to 70 C Relative air humidity non condensing operation 10 to 80 storage 10 to 90 Lows Midrange Highs Profile 1...

Страница 42: ...ng indi cates that these products must not be disposed of with normal household waste but must be disposed of separately at the end of their operational lifetime For packaging disposal please observe the legal regulations on waste segregation applicable in your country Further information on the recycling of theses products can be obtained from your municipal administration from the municipal col ...

Отзывы: