Installing the EM 100 G4
26
Installing the EM 100 G4 in a rack
CAUTION
Rack mounting poses risks
When installing the device in a closed or multi-rack assembly, please con-
sider that, during operation, the ambient temperature, the mechanical
loading and the electrical potentials will be different from those of devices
which are not mounted into a rack.
▷
Make sure that the ambient temperature within the rack does not ex-
ceed the permissible temperature limit specified in the specifications.
See “EM 100 G4”.
▷
Ensure sufficient ventilation; if necessary, provide additional ventila-
tion.
▷
Make sure that the mechanical loading of the rack is even.
▷
When connecting to the power supply system, observe the information
indicated on the type plate. Avoid circuit overloading. If necessary, pro-
vide overcurrent protection.
▷
When rack mounting, please note that intrinsically harmless leakage
currents of the individual power supply units may accumulate, thereby
exceeding the allowable limit value. As a remedy, ground the rack via
an additional ground connection.
Содержание EM 100 G4
Страница 31: ...Installing the SKM 100 G4 30 Battery status Charge status of the batteries Charge status is critical LOW BATT ...
Страница 35: ...Installing the SK 100 G4 34 Battery status Charge status of the batteries Charge status is critical LOW BATT ...
Страница 62: ...Using the EM 100 G4 61 Menu structure The figure shows the complete EM 100 G4 menu structure in an overview ...
Страница 116: ...Specifications 115 Specifications You can find product specific technical data in the sections below ...
Страница 124: ...123 Block diagram ...