background image

 6

REAR PANEL

Power

input

Diamond

RS-422 outputs

The output baud rate is 9600.

Connect to the Diamond receiver

data + and data- lines

S = shield (optional)

FRONT PANEL

Vicon

receive

indicator

Flashes when there
is input data

Diamond

transmit

indicator

Flashes continu-
ously while sending
Diamond data

Power

indicator

The Rx indicator will flash whenever there is data from the Vicon controller. If the input lines have
reversed polarity, the Rx indicator will be on solidly. Diamond data is repeating, so the Tx indicator
will continue to flash while the camera is moving.

If you have Rx but no Tx, possible causes are:

The Vicon code sent to the translator is not camera control code.
The camera address is outside the address window set by the configuration switches.

If the code translator is sending data and does not get a follow-up Vicon command in about 12
seconds, it will time out and quit sending that stream of data.

Vicon

Data input

Connect to the cmd data
lines from the Vicon
controller

Vicon

Rsp output

Connect to the response
data lines from the Vicon
controller (if needed)

INSTALLATION

DIAMOND DATA OUTPUTS

VICON

CMD IN

RSP OUT

POWER

9V to 15V
AC or DC

   S

   S

   S

   S

   S

   S

VICON

Power

Tx

Rx

CODE TRANSLATOR

Содержание SCT-1041

Страница 1: ...1 SCT 1041 Ver 1 2 CAMERA CONTROL CODE TRANSLATOR VICON RS 422 TO DIAMOND RS 422 Ver 1 2 SCT 1041 www sennetech net Sennetech Inc 6455 W Bath Rd Perry MI 48872 U S A Ph 517 675 1150 Fax 517 675 1151...

Страница 2: ...2...

Страница 3: ...ator designed to permit control of Diamond cameras from Vicon controllers It receives Vicon RS 422 commands and transmits the appropriate commands in Diamond Electronics RS 422 format There are four i...

Страница 4: ...y two screws Then slide the cover back to expose the switches The switches can be changed while the code trans lator is powered up and the new settings will take effect immediately SW3 1 GLOBAL IRIS C...

Страница 5: ...59 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 2...

Страница 6: ...the Tx indicator will continue to flash while the camera is moving If you have Rx but no Tx possible causes are The Vicon code sent to the translator is not camera control code The camera address is o...

Страница 7: ...alent Diamond Preshot commands This is the preferred setting as it greatly simplifies bringing up on screen programming menus in the KD6 If SW3 4 is OFF refer to the programming instructions on the fo...

Страница 8: ...t Initialize Dome Find Home Position Display Goto Preshot Menu Display List Preshots Menu Next page Display Program Preshot Menu Display Run Vectorscan Once Menu Display Run Vectorscan Continuously Me...

Страница 9: ...n screen menus and titling that are normally programmed using a computer style keyboard The following commands if preceded by the Vicon L S key are used to generate the same ASCII codes that a keyboar...

Страница 10: ...10 December 2008 SCT 1041 Ver 1 2...