background image

+

_

Data
Input

Data

Output

Power

_

+

Connect power to the Pwr
inputs. Do not connect
power wires to the Gnd.

SCT-100-Pelco-Vicon

Single Camera Code Translator

Pelco RS-422 to Vicon RS-422 Version 1.1

SPECIFICATIONS

Size:

4.5" x 3.5" x 1.25"

Weight:

0.5 lb

Power:

6Volt to 15Volt AC or DC at 75ma

Environmental: Indoor use only

Converts Pelco RS-422 camera control code to Vicon RS-422 code for a single P/T/Z. Only camera
commands for the address matching the Address Selector switches will be converted.

Input Pelco "D" or "P" code at 2400, 4800 or 9600 baud is detected automatically.

Vicon output code is switch selectable for 4800 baud or 9600 baud.

A test mode sends a continuous square movement pattern to the P/T/Z so the wiring and addressing
between the translator and the P/T/Z can be checked without an Pelco controller.

Configuration Switches

Switch 1:  Unassigned

Up:
Down:

Switch 2:  Unassigned

Up:
Down:

Switch 3:  Unassigned

Up:
Down:

Switch 4:   Vicon Output

Up:

9600 Baud

Down:

4800 Baud

Switch 5: Output Camera Address

Up:

Set camera to #1

Down:

Camera address = Input

Switch 6: Output test code

Up:

Output test pattern On

Down:

Output test pattern Off

Removable edge connector.
Insert a small screwdriver in
the upper slot to force open
the wire clamp. Push in all
the way to open fully. Place
stripped wire end(s) in the
open clamp and withdraw
screwdriver.

The removable mounting
clip can be snapped onto a
din rail or screwed to a
panel or wall.

Address Selector

Selects the camera
address. The valid
address range is
001~256

Rx

Indicator

Flashes when
there is data
on the input
lines.

Tx

Indicator

Flashes when
Vicon output
code is sent.

Status

Indicator

Lights if an
invalid test
address is
selected.

Error

Indicator

Flashes on
input error.

Sennetech, Inc.  6455 W. Bath Rd, Perry, MI  48872  U.S.A.   Ph (517) 675-1150  Fax (517) 675-1151

www.sennetech.net