background image

+

_

Data
Input

Data

Output

Power

A C

A C

Rx

Connect power to the AC
inputs. Do not connect
power wires to the Gnd.

Com

SCT-100-Philips232-Pelco

Philips RS-232 to Pelco RS-422 Code Translator

SPECIFICATIONS

Size:

4.5" x 3.5" x 1.25"

Weight:

0.5 lb

Power:

9Volt to 15Volt AC or DC at 75ma
(Optional 24vac operation)

Environmental: Indoor use only

Sennetech, Inc.  3990 Capital City Blvd.  Lansing, MI  48906    Ph (517) 321-1905  Fax (517) 321-8750

The code translator is designed to convert Philips RS-232 camera control code to Pelco RS-422 code
for a single P/T/Z. Only camera commands for the address matching the Address Selector switches
will be converted.

A test mode sends a continuous square movement pattern to the P/T/Z so the wiring and addressing
between the translator and the P/T/Z can be checked without a Philips controller.

Configuration Switches

Switch 1: Pelco Output Code Type

Up:

Pelco "P" code

Down:

Pelco "D" code

Switch 2:  "P" Code Baud Rate

Up:

9600 Baud

Down:

4800 Baud

Switch3: "P" Code Parity

Up:

Even Parity

Down:

No Parity

Switch 4: Not assigned

Up:

Autospeed Enabled

Down:

Autospeed Disabled

Switch 5: Output Camera Address

Up:

Set camera to #1

Down:

Output address = Input

Switch 6: Output test code

Up:

Output test pattern On

Down:

Output test pattern Off

Removable edge connector
Insert a small screwdriver in
the upper slot to force open
the wire clamp. Push all the
way in to open fully. Place
stripped wire end(s) in the
open clamp and withdraw
screwdriver.

The removable mounting
clip can be snapped onto a
din rail or screwed to a
panel or wall.

Address Selector

Selects the camera
address. The valid ad-
dress range is 1~999

Rx

Indicator

Flashes when
there is data on
the input lines.

Stays on if the
input lines are
reversed.

Tx

Indicator

Flashes when
camera control
code is sent.

Status

Indicator

Lights if an
invalid address
is selected.

Error

Indicator

Flashes on input
error.

Отзывы: