background image

RS-422

Data

Input

Connect power to the PWR
inputs. Do not connect
power wires to the Gnd.

SCT-100-Pelco-Visca

Pelco RS-422 to Visca RS-232 Camera Code Translator V2.0

SPECIFICATIONS

Size:

4.5" x 3.5" x 1.25"

Weight:

0.5 lb

Power:

9~15Volt AC or DC at 75ma

Environmental: Indoor use only

Sennetech, Inc.  6455 W. Bath Rd. Perry, MI  48872,  U.S.A.    Ph (517) 675-1150  Fax (517) 675-1151

The code translator converts Pelco RS-422 camera control code to Sony Visca RS-232 code for a
single Sony camera.

Input Pelco "D" or "P" code at 2400, 4800 or 9600 baud is detected automatically.
Visca RS-232 output is selectable from 4800 baud to 38400 baud.

A test mode sends a continuous square movement pattern to the camera so the wiring and addressing
between the translator and the camera can be checked without a Pelco controller.

Address Selector

Selects the camera
address. The valid
address range is
001~256

Configuration Switches

Switches 1 &2: Visca Baud

1 Off     2 Off

4800

1 On     2 Off

9600

1 Off     2 On

19.2k

1 On     2 On

38.4K

Switch 3: Set Camera Address

On:              Send "set address cmd"
Off:

Switch 4: Reverse Pan/Tilt

On:              Reverse P/T Directions
Off:              Normal P/T Directions

Switch 5: Unassigned

On:
Off:

Switch 6: Test Mode

On:

On

Off:

Off

Removable edge connector
Insert a small screwdriver in
the upper slot to force open
the wire clamp. Push in all
the way to open fully. Place
stripped wire end(s) in the
open clamp and withdraw
screwdriver.

The removable mounting
clip can be snapped onto a
din rail or screwed to a
panel or wall.

Rx

Indicator

Flashes when
there is data on
the input lines.

Tx

Indicator

Flashes when
Visca output
code is sent.

Status

Indicator

Lights if an
invalid address
is selected.

Error

Indicator

Flashes on
input error.

www.sennetech.net

RS-232

Data

Output

Отзывы: