SENLAN INVERTER
USER’S MANUAL
SB150 Variable Speed Drive
Hope Senlan Science & Technology Holding Corp., Ltd.
Страница 1: ...SENLAN INVERTER USER S MANUAL SB150 Variable Speed Drive Hope Senlan Science Technology Holding Corp Ltd...
Страница 2: ...commissioning 20 4 1 Operation and display 20 4 3 Quick and optimize commissioning 23 5 Parameter table 25 7 Troubleshooting 69 7 1 Faults and remedies 69 7 2 Alarms and remedies 71 7 3 Operation fau...
Страница 3: ...tenance The technical specifications applied to this product or the content of this manual may be subject to any change without prior notifying This manual is required to be kept properly until the in...
Страница 4: ...ing markings for identification The user is required to follow the instructions of the content identified with safety markings CAUTION Any wrong operation or against the instructions may cause inverte...
Страница 5: ...ectric fire 3 Check before switching on the power Close the cover board of the inverter before turning on the power otherwise there may be a risk of electric shock or explosion Before trying to run th...
Страница 6: ...g Constant torque low speed operation When a common motor runs at low speed for a long time the motor temperature will rise due to the weakening cooling effect So if a motor is required to operate at...
Страница 7: ...nverter input side to start or stop the inverter frequently is prohibited That may destroy the inverter Using the inverter beyond the rated value It is not recommended to operate the inverter beyond t...
Страница 8: ...b If the altitude is above 1000 meters the inverter should be derated by 1 for every 100m rise c If the carrier frequency is greater than the factory setting the inverter should be derated by 5 for e...
Страница 9: ...Command source Keypad terminal and communication They can be switched over by terminals Frequency reference source Keypad keys and POT communication UP DOWN value AI1 AI2 and PFI Auxiliary frequency...
Страница 10: ...n Storage temperature 20 60 Ambient Vibration Less than 5 9m s2 0 6g Protection degree IP20 Structure Cooling method Forced air cooling with fan control 2 2 Product series SB150 inverter rated value i...
Страница 11: ...key stop fault reset Description of keys on the keypad Key Name Function Menu Enter 1 Enter each menu 2 Data storage confirmation Shift Exit 1 Select the data digit to be modified switch between moni...
Страница 12: ...cation control 4 1 2 Display status and operation of keypad The keypad of SB150 has the following display status monitoring status including in standby state and in run state parameter editing status...
Страница 13: ...parameter is displayed Password check status If there is a user password F0 12 not equal to zero before you can edit any parameter you enter the password check status and is displayed Input the passw...
Страница 14: ...ency setting is digital setting refer to 3 4 1 to check the terminal function Below is some common and necessary settings of SB150 inverter besides default setting 1 Frequency setting channel and refe...
Страница 15: ...4 Operation and commissioning 24 4 Vibration damping If the motor vibrates increase this parameter gradually until the vibration disappears Refer to F2 06...
Страница 16: ...7 F0 03 Frequency holding 0 Saved upon power loss 1 Restored to F0 00 upon power loss 2 Restored to F0 00 upon power loss or stop Note For keypad digital potentiometer revise by or communication setti...
Страница 17: ...ode 0 Slowdown stop 1 Coast stop 2 Slowdown DC braking 0 40 F1 09 DC braking frequency at stop 0 00 60 00Hz 0 50Hz 40 F1 10 DC braking waiting time 0 0 10 0s 0 0s 40 F1 11 DC braking Zero speed delay...
Страница 18: ...or parameters No Name Setting range Default Cha nge Page F3 00 Motor rated capacity 0 40 1 5kW Depends on model 44 F3 01 Pole number 2 16 4 45 F3 02 Motor rated current 0 5 7 5A Depends on model 45 F3...
Страница 19: ...t stop direction 5 3 wire mode 1 FWD REV stop 6 3 wore mode 2 run direction stop 1 45 F4 07 UP DOWN regulation mode 0 Level type terminal 1 Pulse type terminal 2 Level type keypad 3 Pulse type keypad...
Страница 20: ...a nge Page F6 00 AI1 Min input analog quantity 0 51 F6 01 AI1 Max input analog quantity 0 00 100 0 100 0 51 F6 02 AI1 Min input analog quantity corresponding set value feedback value 0 00 51 F6 03 AI1...
Страница 21: ...channel 0 F7 04 1 AI1 2 AI2 4 AI1 AI2 6 keypad potentiometer value 3 AI1 AI2 5 UP DOWN value 7 Communication setting 0 55 F7 02 feedback channel 1 AI1 3 AI1 AI2 2 AI2 4 AI1 AI2 1 55 F7 03 PID referenc...
Страница 22: ...quency 100 1 Max frequency 100 0 58 F9 02 Preset wobble frequency F0 08 F0 07 0 00Hz 58 F9 03 Preset wobble frequency waiting time 0 0 3600 0s 0 0s 58 F9 04 Wobble frequency amplitude 0 0 50 0 relativ...
Страница 23: ...et times 0 10 module protection and external fault have no reset function 0 62 Fb 09 Auto reset interval 1 0 30 0s 5 0s 62 Fb 10 Fault output during auto reset 0 No output 1 Output 0 62 Fb 11 Power on...
Страница 24: ...F 00 Communication data format 0 8 N 1 1 8 E 1 2 8 O 1 3 8 N 2 0 64 FF 01 Baud rate selection 0 1200bps 1 2400bps 2 4800bps 3 9600bps 4 19200bps 3 64 FF 02 Local address 1 247 248 is master 1 64 FF 03...
Страница 25: ...it 0 01Hz FP 03 Reference frequency at last fault Min unit 0 01Hz FP 04 Output current at last fault Min unit 0 1A FP 05 Output voltage at last fault Min unit 0 1V FP 06 Output capacity at last fault...
Страница 26: ...t fault Min unit 0 1V FP 36 Output capacity at 4th last fault Min unit 0 1kW FP 37 DC link voltage at 4th last fault Min unit 0 1V FP 38 Bridge temperature at 4th last fault Min unit 0 1o C FP 39 Term...
Страница 27: ...voltage Min unit 0 1V FU 08 Output capacity Min unit 0 1kW FU 09 Operating line speed Min unit 1m s FU 10 Reference line speed Unit indicator blinks Min unit 1m s FU 11 PID feedback Min unit 0 1 FU 12...
Страница 28: ...hange of load Reduce the sudden change of the load load error Check the load Low power grid voltage Check the input power E ocn 4 Overcurrent during constant speed operation Inverter capacity too smal...
Страница 29: ...ter E EEF 16 External fault External fault terminal closed Deal with the external fault Improper setting of communication parameters Check the settings of FF menu Serious communication interference Ch...
Страница 30: ...22 Reserved 7 2 Alarms and remedies Alarm code Alarm name Description Remedies Alarm word Bit A oLL Motor overload Motor thermal model detects the motor temperature rise is overhigh Refer to above tab...
Страница 31: ...is off Run command channel switches over Check the operation and run command channel status Waiting for the fault auto reset Check auto reset setting Reference frequency is zero Check reference freque...
Страница 32: ...f the inverter meets the requirement 2 If the operating parameters of the inverter are set within the specified ranges 3 If there is any unusual vibration or noise 4 If there is any unusual odor 5 If...
Страница 33: ...mmended to replace the bus electrolytic capacitor once every four or five years 8 3 Storage of the inverter Avoid storing the inverter in a place with high temperature humidity dust and metal powder L...
Страница 34: ...8 Maintenance and After sale Service 75 and design within the warranty period For a rectification beyond the warranty period we will charge the user as required at a reasonable rate...