background image

MI000405-I-E

ENGLISH 4/8

I n   c a s e   o f   Z - P C -D I N A L 2 -1 7 , 5

accessory  use,  the  signals  may  be

provided by terminal blocks. The figure

shows the meaning of the terminals and

the position of the DIP-switch (present

on  each  DIN  rail  supports  listed  on

Accessories)  for  network  termination

(not used in case of Modbus network).

GNDSHLD: Shield to protect the signal

inside  the  connection  cables  from

e l e c t r o m a g n e t i c   d i s t u r b a n c e s

( recommended).

Z-PC-DINAL2-17,5 Accessory Use

In the figure the meaning of the IDC10

connector pins is showed, in the case

the user decides to provide the signals

directly through it.

Rear Connector (IDC10)

RS485 GND

Power Supply AC +

RS485 A

RS485 B

Power Supply AC-

IDC 10

1

ELECTRICAL CONNECTIONS

Power Supply and Modbus Interface

Power Supply and CAN/MODBUS interface are available by using the bus for the Seneca

omega rail, by the rear IDC10 connector or by Z-PC-DINAL2-17,5 accessory.

As it is illustrated in the next figure:

1) 

two

Pull the 

 latches (placed in the back of the

module) outwards.
2) Insert the rear IDC10 connector on a rail free

slot  (the  inserting  is  univocal  since  the

connectors are polarized).
3) Push the two latches (placed in the back of the

module) in order to lock the module on the rail.

Inserting on the DIN rail

Inserting on

omega rail

IEC EN 60715

Module

omega

rail

INSTALLATION RULES

The module is designed to be installed in vertical position on a omega IEC EN 60715 rail.

In order to ensure optimum performance and the longest working life, the  module(s) must

be  supplied  adequate  ventilation  and  no  raceways  or  other  objects  that  obstruct  the

ventilation  slots.  Never  install  modules  above  sources  of  heat;  we  recommend

installation in the lower part of the control panel.

ENGLISH 3/8

MI000405-I-E

ADDITIONAL NOTES

:

A max 2.5 A delayed fuse shall be installed near the module.

Standards

The module complies with the following standards:

EN61000-6-4

  (electromagnetic  emission,

industrial environment).

EN61000-6-2

  (electromagnetic  immunity,

industrial environment)

EN61010-1

 (safety).

Isolations

1500 V

Dimensions / Box

Dimensions

L: 100 mm; H: 112 mm; W: 17.5 mm

Box

PA6, Black color

Connections

Power Supply, Outputs, RS485

Removable 3-way screw terminals, 5,08 mm pitch

Power Supply, RS485

Rear IDC10 connector for CEI EN60715 rail

Environmental Conditions

Temperatura

-20 – +65°C

Humidity

30 – 90% at 40°C non condensing

Altitude

Up to 2000 m a.s.l.

Storage Temperature

-20 – +85°C

Protection degree

IP20

Power Supply

Voltage

10 – 40 V ; 19 - 28 V  50 – 60 Hz

Consumption

Max: 2.5 W

MI000405-I-E

ENGLISH 2/8

GENERAL SPECIFICATIONS

5 SPST relay outs N.O. with common line, capacity 3 A-250 V  resistive, 5 A inductive.

Max output common relays current 12 A

Pull-out screw terminals, section 2.5 mm .

2

Capability of set relays as N.O. or N.C. (rest status).

You may set the safety status at start-up or if there isn’t communication.

The safety time can be set from 0,5 s to 2,5 s.

Possibility of ON-LINE configuration.

RS485 serial communication with Modbus Rtu protocol, maximum 32 nodes.

Communication speed from 1200 Baud to 115k Baud.

3000 V  output insulation with respect to remaining low voltage circuits.

Power supply and serial connection wiring facilitated by means of a bus that can be

  housed in the DIN guide. The terminals can still be used.

Insertion into and removal from bus without interrupting communication or system

  power supply.

Communication times below 10 ms (@ 38400 Baud).

Connection distance up to 1200 m.

ENGLISH 1/8

MI000405-I-E

This document is property  of SENECA srl. Duplication and reprodution are forbidden, if not   authorized.

Contents of the present documentation refers to products and technologies described in it. All technical

data contained in the document may be modified without prior notice. Content of this documentation is

subject to periodical revision.

SENECA s.r.l.

Via Austria, 26 – 35127 – PADOVA – ITALY

Tel.  +39.049.8705355 - 8705359  -  Fax +39.049.8706287

 For manuals and configuration software, please see: www.seneca.it

Installation

Manual

Contents:

- General Specifications

- Technical Specifications

- Installation Rules

- Electrical connections

- Modbus connections rules

- DIP-switches settings

- Digital inputs

- Leds Signallings

- Factory Settings

Installation

Manual

Modbus Module with

5 relay for Digital Outputs

Modbus Module with

5 relay for Digital Outputs

Z-D-OUT

Z-D-OUT

Z-PC Line

Z-PC Line

EN

EN

