5.7
Setup
5.7.1
Setup — Params
The Setup — Params view enables the following settings:
Various
Extractor name:
Each Extractor can be assigned a user defined name.
Extractor location:
A text string describing the location of the Extractor.
EBU mode:
Selects the unit to use for loudness monitoring. In EBU mode, LUFS is used,
otherwise LKFS is used.
Alarms
Freeze log when full:
When enabled the alarm list will freeze when full (an event will show that it
is full). When the list is full new alarms are ignored until Clear alarms is
pressed. This can sometimes be useful if a unit is placed unattended.
Treat events as alarms:
When enabled each event is treated as an alarm that is active for 5
seconds. This may be useful when reporting to external systems that do
not support events but only active or cleared alarms. This setting affects
the local alarm list, SNMP traps and syslog messages.
Network settings
Source specific multicasts:
This option should be enable to use Source-specific multicasts.
Time synchronization
VB7880 Advanced Content Extractor User’s Manual version 5.2
73