6.4.7
Multicasts — Ethernet thresh.
Thresholds are used to determine when to actually raise an alarm upon detection of an error. The Ethernet
thresholds are used for generating Ethernet probe alarms as well as for calculating error-seconds. Error
seconds and ETH probe alarms are issued whenever measurements exceed the defined threshold levels
for a parameter. Ethernet thresholds are also used to scale some graphs like the MediaWindow graphs.
The alarm level of each of these alarms is set in the
view. Note that it is also
possible to disable alarms in the
view.
The
Multicasts — Ethernet thresh.
view makes it possible to define threshold values that operate at
stream level. Thresholds are associated with each stream in the
view.
There are two different ways of creating user-defined thresholds. To create a new threshold template
from scratch the operator should click the
Add new threshold
button. A pop-up window will appear
allowing the user to define alarm conditions. Another way of creating a user-defined threshold template is
by highlighting one of the threshold templates already defined and then click the
Duplicate highlighted
button.
Deleting a threshold template is done by highlighting the threshold template that should be removed and
clicking
Delete selected
. It is possible to delete or edit several entries simultaneously. Several entries
are selected by using the regular
Ctrl + click
or
Shift + click
functionality. Click the
Edit
button to edit one
or more selected threshold templates. Note that the predefined ‘Default’ threshold template cannot be
deleted or changed.
In the threshold presets list the ‘Refs’ column displays how many streams are associated with each
stream threshold template.
VB3xx 10G Probe User’s Manual version 5.3
85
Содержание VB330
Страница 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Страница 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Страница 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Страница 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Страница 101: ...VB3xx 10G Probe User s Manual version 5 3 101...
Страница 149: ...The PID threshold template has the following settings VB3xx 10G Probe User s Manual version 5 3 149...