6.4
Multicasts
6.4.1
Multicasts — Parameters
The
Multicasts — Parameters
view displays detailed information about each stream.
The user selects which group of measurements should be displayed. Selections are
IP parameters
,
TS
parameters
,
Ethernet parameters
,
RTP and FEC parameters
,
User-defined parameters
and
Statistical
parameters
. If
User-defined parameters
is selected, the
Multicasts
view displays parameters selected
by the user in the
Multicasts — Parameters — Fields
view.
For each page the
Accumulated
row at the bottom of the multicast list displays accumulated values for all
streams associated with the page. The accumulated
Min bitrate
and
Max bitrate
is the minimum and
maximum value of the
Accumulated
current bitrate.
When the
Current page
button is clicked it is possible to select the page from a drop-down menu. The
associated thumbnails are shown in the leftmost column of the list of measurements. Click one of the
small thumbnails to view a larger thumbnail that is updated more frequently. Note that it is possible to
disable probe thumbnail extraction in the
view.
When
All streams (offline)
is clicked a complete list of measurements for all joined streams is displayed.
A search field allows the user to type a text string and the multicast list is updated to display only
multicasts matching the specified text. Note that monitoring parameters and thumbs will not be updated
in
All streams (offline)
mode.
64
VB3xx 10G Probe User’s Manual version 5.3
Содержание VB330
Страница 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Страница 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Страница 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Страница 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Страница 101: ...VB3xx 10G Probe User s Manual version 5 3 101...
Страница 149: ...The PID threshold template has the following settings VB3xx 10G Probe User s Manual version 5 3 149...