![Sencore VB330 Скачать руководство пользователя страница 194](http://html1.mh-extra.com/html/sencore/vb330/vb330_user-manual_1239233194.webp)
As we have seen, there is no sure way to distinguish between UDP packet-loss and loss in the underlying
TS packets. One way to deal with the situation is to have a probe doing zero readings close to the signal
source before the network can introduce UDP packet loss.
B.4
Multicast Thresholds
It is useful to configure individual threshold settings for IAT for each stream unless they are fixed at the
same bit-rate. Streams that are being monitored by several probes should have equal Ethernet thresholds
configured on each probe to make it easy to compare measurements for a stream across several probes.
As a rule of thumb the IAT warning threshold could be set to 50% above the max IAT value observed
over a considerable period of time, the last 24h or so. The IAT error threshold could be set a little
below the maximum jitter the system can tolerate – usually limited by the STB jitter tolerance. STB
manufacturers should be able to provide information about how much jitter they can handle. Setting the
Ethernet warning-threshold too high results in a graph where almost all plots are close to the x-axis and
it becomes less useful to visually compare MediaWindow graphs.
For streams with TS/UDP mapping the default MLR threshold is set so that errors are reported if the
number of CC errors exceeds the number of TS packets in one UDP frame (assumed to be 7).
B.5
Dedicated interface for OTT
As a rule of thumb, you should never have OTT traffic on the same network as multicasts. This means
that you should either use one 10G Probe for multicast and one for OTT, or you should use different and
dedicated interfaces for each.
The interface used for OTT traffic is controlled using the
view.
B.6
OTT Bandwidth requirements
The recommended available bandwidth for full coverage OTT monitoring is equal to the sum of the profile
bitrates monitored plus an estimated overhead of 20 % for manifests and IP, TCP and HTTP headers.
Note:
The OTT engines will be using all available bandwidth on the interface in spikes while downloading
the chunks, this is the main reason why it is not a good idea to mix multicasts on the same interface, as it
can cause packet drops which multicasts cannot handle.
194
VB3xx 10G Probe User’s Manual version 5.3
Содержание VB330
Страница 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Страница 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Страница 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Страница 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Страница 101: ...VB3xx 10G Probe User s Manual version 5 3 101...
Страница 149: ...The PID threshold template has the following settings VB3xx 10G Probe User s Manual version 5 3 149...