231 (0xe7):
‘Disabled’ or ‘private cable delivery system descriptor’
233 (0xe9):
‘Disabled’ or ‘ip_delivery_system_descriptor’
The default value for private descriptors is ‘Disabled’. To change this value, select a new descriptor
interpretation from the drop-down menu and click the
Apply changes
button.
6.10.9.2
ETR 290 tuning control
By default authorized users will be allowed to lock the ETR 290 analysis to one stream for an infinite
length of time and unauthorized users will not be allowed to lock the analysis. The
Setup — ETR
view
makes it possible to time limit the locking for authorized users and unauthorized users can be granted
permission to lock to a stream for a selectable time period.
If the locking mechanism works in a time limited mode a clock icon (see image above) is superimposed
on the regular lock icon in the different
ETR 290
subviews. When the specified lock time is out the
round-robin cycling will resume. When ETR tuning control parameters have been changed, click the
Apply
button for changes to take effect.
6.10.9.3
ETR details
The user selects if service names should be displayed in the
view. Note that a
large screen size is required for proper service name displaying.
6.10.9.4
EIT table IDs
The user defines which DVB EIT table IDs should be analyzed by the probe. By default only table ID 78
(EIT p/f actual) is analyzed.
172
VB3xx 10G Probe User’s Manual version 5.3
Содержание VB330
Страница 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Страница 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Страница 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Страница 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Страница 101: ...VB3xx 10G Probe User s Manual version 5 3 101...
Страница 149: ...The PID threshold template has the following settings VB3xx 10G Probe User s Manual version 5 3 149...