specified with the rest, where the msgSlot field is the slot, msgPort is the port on the slot, while
the msgInstance field is used when further differentiation is necessary.
The other fields correspond to the fields in the GUI: the msgSeverity field to Level, the
msgSourceName field to Application, the msgText field to Error Code, and the
msgGenerationTime field to Set.
For more information on using the SNMP agent, refer to the
SNMP Integration
Guide
.
11.3 SOAP XML Interface
The SOAP XML interface can be used for external control and monitoring of the unit. For more
information on the SOAP XML interface, refer to the
Sencore SOAP XML API
document.
12 Maintenance
This chapter describes how to perform maintenance tasks such as software upgrades,
replacing faulty modules, etc.
12.1 Software Upgrades
Software can be uploaded to the unit remotely using the Maintenance Center (MC) available on
port 8088 of the unit, ie http://<ip_addr>:8088/. Refer to the
Upgrade Guide
for details.
Required software upgrades for the units will be provided together with instructions by
Sencore’s support department.
For more details on the upgrade procedure, please refer to the Upgrade Guide document.
12.2 Hot-Swapping
The platform supports module hot-swapping, i.e. the different modules – power supply, fan,
input, or switch – can be replaced when the head-end is in operation, without shutting it down.
In other words, removing a module and replacing it with a new one will not damage the module.
The effects of hot-swapping a module are explained in further detail in the following sections.
12.2.1 Performing a Hot-Swap
To remove a module, first loosen the screws on the top and bottom (one screw is located in the
ejector). Next, press the white button inside the module ejector and push the ejector down. The
module is now released from the chassis.
To insert a new module into the chassis, it is important to align the module’s edges with the
module-guides in the chassis. Ensure that the jack on the module is in the open position as
illustrated in the figure below. Slide the module into the unit on the module-guides until the jack
touches the chassis. Move the jack upwards. This will insert the module all the way into the unit.
Содержание DMG 3000
Страница 36: ...DMG 3200 3100 3000 User Manual Page 36 306 Figure 4 7 IPv6 Address in Admin Page Figure 4 8 Manual IPv6 Address...
Страница 65: ...DMG 3200 3100 3000 User Manual Page 65 306 Figure 5 24 QAM Status View...
Страница 69: ...DMG 3200 3100 3000 User Manual Page 69 306 Figure 5 27 COFDM Status View...
Страница 74: ...DMG 3200 3100 3000 User Manual Page 74 306 Figure 5 29 Edit IP Port...
Страница 80: ...DMG 3200 3100 3000 User Manual Page 80 306 Figure 5 35 T2MI De Encapsulation for IP Input configuration...
Страница 119: ...DMG 3200 3100 3000 User Manual Page 119 306 Figure 6 28 Adding an EIS...
Страница 167: ...DMG 3200 3100 3000 User Manual Page 167 306 Figure 7 57 Packets dropped in Output View...
Страница 277: ...DMG 3200 3100 3000 User Manual Page 277 306 Figure 10 28 Encoder redundancy topology...
Страница 303: ...DMG 3200 3100 3000 User Manual Page 303 306 Figure 12 4 DIP switch ON DMG 3200...
Страница 306: ...Sencore Inc 3200 Sencore Drive Sioux Falls SD 57107 USA www sencore com Copyright 2014 Sencore Inc 1 605 978 4600...