background image

1

Operating Instructions

   Warnings for the safe use of this compressor are included in this manual.

PC 1001 

Electric Air Compressor

Document #FN1001 Issued 5/30/A

Questions? Comments? call SENCO’S toll-free Action-line: 1-888-222-8144 or, e-mail: [email protected]

Code 181517022

Содержание PC 2001

Страница 1: ...r the safe use of this compressor are included in this manual PC 1001 Electric Air Compressor Document FN1001 Issued 5 30 A Questions Comments call SENCO S toll free Action line 1 888 222 8144 or e ma...

Страница 2: ...5 BREATHING 6 BURNS 6 FLYING OBJECTS 6 MOVING PARTS 7 NEGLIGENCE 7 AIR COMPRESSOR DAMAGE 7 COMPRESSOR FEATURES 8 PREPARATION 10 INITIAL SET UP 10 LOCATION 10 ELECTRICAL 10 OPERATION 11 PRE START CHECK...

Страница 3: ...ot avoided WILL result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury CAUTION Indicates a potentially hazar...

Страница 4: ...electrical cords to lay in water or in such a position where water could come in contact with them Do not touch plug with wet hands Do not pull on the electrical cord to disconnect from the outlet Nev...

Страница 5: ...ble dust gases or other combustible materials If spraying flammable material locate the air compressor at least 20 feet away from the spray area An additional hose may be required Never place objects...

Страница 6: ...from the air compressor either directly or from a breathing device connected to the air compressor Operate air compressor only in a well ventilated area Follow all safety instructions provided with t...

Страница 7: ...restart at any time Do not operate without protective covers guards Replace damaged covers guards before using the air compressor Never allow children or adolescents to operate this air compressor St...

Страница 8: ...ressor Pump 5 Safety Relief Valve 6 Air tank drain valve 7 Tank Pressure Gauge 8 Outlet Pressure Gauge 9 Pressure Regulator 10 Oil Dipstick 11 Oil Drain 12 Discharge Line 13 115 Volt Electric Power Co...

Страница 9: ...tons move up and down in the cylinders On the downstroke air is drawn in through the air intake valves while the exhaust valves remain closed On the upstroke air is compressed the intake valves close...

Страница 10: ...sary do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire WARNING This pr...

Страница 11: ...less pressure and clockwise for more pressure 6 If you notice any unusual noise or vibration stop the air compressor and refer to Troubleshooting SHUTDOWN 1 To stop the air compressor move the lever...

Страница 12: ...e Plug cord into grounded outlet Move switch to AUTO position Turn air compressor off wait until motor is cool then press motor thermal overload red button firmly until click is heard Replace fuse or...

Страница 13: ...city of the air compressor Either use a smaller tool or a larger air compressor REMEDY Remove clean or replace REMEDY Replace REMEDY Operate safety relief valve manually by pulling on ring If it still...

Страница 14: ...st pressure regulator knob to proper setting or replace Clean or replace Check for leaks and repair Replace with larger hose or connectors Check the accessory air requirement If it is higher than the...

Страница 15: ...linder Steel sleeve inserts Valves Reed Single Head Aluminum Filter Canister Motor Pressure Switch Setting Cut out 116 PSI Cut in 87 PSI Controls Start stop Air tank Capacity 4 3 gallons Performance C...

Страница 16: ...improper storage or damages resulting during shipping 4 Deviation from operating instructions specifications and maintenance schedules 5 Labor charges loss or damage resulting from improper operation...

Отзывы: