1
Parani-SD100L/200L
User Guide
Version 1.0.0
2006-09-18
Страница 1: ...1 Parani SD100L 200L User Guide Version 1 0 0 2006 09 18...
Страница 2: ...mmended Electrical shock may result Do not kink or crease the power cable or place heavy objects on the power cable Fire can result from damaged power cables Do not handle power plug and adapter with...
Страница 3: ...Terminal Program 20 4 Approval Information 22 4 1 FCC 22 4 1 1 FCC Compliance Statement 22 4 1 2 RF Exposure Statement 22 4 1 3 Do not 22 4 2 CE 22 4 2 1 EC R TTE Directive 22 5 RF Information 23 5 1...
Страница 4: ...Force to Reconnect default 1 38 C 2 S2 Enable Hardware Flow Control default 1 38 C 3 S3 Stream UART Policy default 0 38 C 4 S4 Enable Remote Name Query default 1 38 C 5 S6 Enable Low Power Mode defau...
Страница 5: ...5 D 2 2 AT Response 41 D 3 Transmission Delay 42 D 3 1 RF Processing Delay 42 D 3 2 RF Transmission Environment 42...
Страница 6: ...izes the quality and distance of wireless communications Parani SD can be configured and controlled by typical AT commands User can easily configure Parani SD on the terminal program such as HyperTerm...
Страница 7: ...uration ParaniWIN Modem AT command set Firmware Update ParaniUpdater for SD ESD Diagnostic LED Power Charging finish Standby Charging Connect Serial RX Serial TX Supply voltage DC 5V 2A AC100 240V 50...
Страница 8: ...power the serial device and the battery pack to the Parani SD Series Following items are pre required to get started One DC power adapter USB power cable or DC power cable included in the package One...
Страница 9: ...Parani SD Connect the power jack to the power connector of the Parani SD Series using the DC power adapter USB power cable or DC power cable that is included in the package If power is properly suppl...
Страница 10: ...the last connected Bluetooth device Parani SD in Mode1 is to be a master and tries to connect the last connected Bluetooth device Parani SD always stores the BD address of the Bluetooth device to whic...
Страница 11: ...No parity Even parity Odd parity Stop bit 1 2 Hardware Flow Control Use No Use The values in box are the factory defaults The flow control setting is configurable only through dip switch 3 3 1 Data Bi...
Страница 12: ...button with a narrow pointed tool like paper clip longer than 1 second Reset works only when power is on 3 3 4 Dipswitch This feature is only on Parani SD205 With the combination of 4 slot dipswitche...
Страница 13: ...Turn SD2 off and on Connect LED blinks once in green every 1 second Step 8 Now a pair of Parani SD is configured to make automatic connection whenever power off and on Just use this pair of Parani SD...
Страница 14: ...omputer and turn on the power Run ParaniWIN Figure 3 2 Serial Port Setting Set each option properly and click Confirm If the settings are different from the host computer error message will pop up If...
Страница 15: ...15 Figure 3 4 Main Window Figure 3 5 Information Window...
Страница 16: ...Figure 3 7 Device Setting Window Parani SD supports two security options Authentication and Encryption If you check the Authentication option you must also enter the Pin Code value If the authenticati...
Страница 17: ...will be disabled Click Apply button to reflect the given options to Parani SD actually Connect out icon will show the following window to search and connect other Bluetooth devices Figure 3 8 Connect...
Страница 18: ...rminate the sensitivity test The sensitivity test will continue until the STOP button is pushed If you close the ParaniWIN Window without pushing the STOP button you must restart Parani SD to terminat...
Страница 19: ...19 Figure 3 10 Connection in Window If the Connection Wizard icon is clicked an easy pairing menu to use appears as follows Figure 3 11 Connection Wizard Window...
Страница 20: ...ing connection will be established automatically 3 3 8 ParaniUpdater Parani SD support firmware update You can download new firmwares of Parani SD at http www sena com With ParaniUpdater you can updat...
Страница 21: ...iguration window as Parani SD settings The settings need to be set correctly otherwise error message may be shown up on the screen or cause malfunctioning of Parani SD Figure 3 13 HyperTreminal Choose...
Страница 22: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged...
Страница 23: ...ncy Hopping Spread Spectrum 5 4 Modulation Method GFSK Gaussian filtered Frequency Shift Keying 5 5 Radio Output Power Products Transmit Power SD100L 18dBm SD200L 2dBm 5 6 Receiving Sensitivity Produc...
Страница 24: ...emale connector Table A 1 Pin assignment of the DB 9 female connector Pin Signal Direction Description 1 CD Output Received Line Signal Detect 2 TxD Output Transmitted Data 3 RxD Input Received Data 4...
Страница 25: ...25 A 2 1 To Host with DTE Interface A 2 2 To Host with DCE Interface...
Страница 26: ...onse Parani SD replies to AT commands with 4 kinds of message OK ERROR CONNECT and DISCONNECT B 1 2 Operation Mode Mode Description Mode0 Waiting for AT commands Mode1 Attempting to connect the last c...
Страница 27: ...egory Index AT Commands RESET 1 2 ATZ AT F SERIAL PORT 3 4 5 AT AT UARTCONFIG b p s AT USEDIP Information 6 7 8 AT BTINFO AT BTINQ AT BTLAST Mode 9 AT BTMODEn Status 10 11 12 13 14 15 16 AT SETESC nn...
Страница 28: ...ly Reference ATZ B 3 3 AT SD Response OK Purpose Check the connection status with host equipment Description Check if the connection to host equipment is normal The serial parameters of Parani SD must...
Страница 29: ...E0 MODE1 MODE2 MODE3 Status STANDBY PENDING CONNECT Auth 0 1 Authentication is not activated when 0 Encrypt 0 1 Encryption is not activated when 0 FlowControl HWFC NoFC Reference AT BTNAME AT BTMODE A...
Страница 30: ...use this command in Stanby status The sensitivity will be displayed repeatedly in order of Status LinkQuality Status RSSI If the LinkQuality is close to 255 and RSSI is close to 0 the sensitivity is...
Страница 31: ...escape sequence character by default which is changeable by AT SETESC Reference AT SETESC ATO AT BTCANCEL B 3 13 AT SETESC nn SD Response OK Purpose Change the escape sequence character Description E...
Страница 32: ...om other Bluetooth devices If the parameter of to is 0 it will wait forever When connection is made with other Bluetooth device SD response will be CONNECT with its BD address If there is no connectio...
Страница 33: ...connection the Bluetooth device must be in Page scan This attempt continues for 5 minutes If it fails to make connection SD response is ERROR Reference AT BTINQ AT BTSCAN Example ATD000B530011FF B 3...
Страница 34: ...use the main memory still has the list Reference AT BTFP AT BTKEY AT BTSD AT BTSEC ATZ AT F B 3 25 AT BTFP n SD Response OK Purpose Set generation of link key every time of connection Parameters n 0 I...
Страница 35: ...n Parani SD can be in low power mode to save the power consumption It takes a few seconds to wake up Parani SD in low power mode B 3 29 AT DFU SD Response Display garbage messages repeatedly Purpose D...
Страница 36: ...ion Some S registers are optimized for the overall performance and protected from an arbitrary change by user When users try to change these S registers SD response is ERROR For details of S register...
Страница 37: ...n AT BTINFO AT BTLPM n AT BTSD AT BTCSD AT BTFP n AT UARTCONFIG b p s AT USEDIP AT BTVER AT DFU AT BTRSSI n Valid only when Parani SD is not connected to other Bluetooth device Valid only when Parani...
Страница 38: ...mall data quickly This value decides the way of handling stream data from UART When this value is 1 in order that SD minimizes the latency SD sends the received data immediately When this value is 0 i...
Страница 39: ...cannot be changed to Standby As Parani SD skips the process detecting escape sequence character the more efficient data transmission is expected S11 1 Parani SD allow escape sequence character Wheneve...
Страница 40: ...he SD will restart automatically If this value is 0 SD will attempt to connect without restarting C 15 S33 Inquiry Timeout default 30 This is the timeout in seconds to execute inquiry scan C 16 S37 Su...
Страница 41: ...ni SD are same as those of its host equipment Parani SD supports No parity Even parity and Odd parity 1 and 2 Stop bit Check whether the host equipment of Parani SD uses Hardware Flow Control Parani S...
Страница 42: ...oth device This time delay cannot be reduced and would be bigger as the RF transmission environment is bad Do not use Parani SD If your applications cannot allow this time delay D 3 2 RF Transmission...