© by SEMIKRON / 2020-05-25 / Technical Explanation / SKYPER
®
12 PV
PROMGT.1026/ Rev.7/ Template Technical Explanation
Page 32/37
7.
Product Qualification
Table 9: SKYPER
®
12 PV | Routine tests
test
test category
test description
Standard
AOI
Automated
Opt. Inspection
Control of accurate placement of
components/ of solder joints, 100%
SEMIKRON
ICT
In-Circuit Test
Test of the populated PCB, checking the
correctly fabrication, 100%
SEMIKRON
FAT
Function Test
Supply current, gate on/off, UVP, error,
100%
SEMIKRON
Table 10: SKYPER
®
12 PV | Approval tests
test
test category
test description
1
Standard
EP
Electrical Parameters
amb = -40°C / +85°C
SEMIKRON
ST
STEP Test
20x 10µs to 2s interruption
IEC 61000-4-29
ISO
Isolation
5.0 kV AC rms, 60s
IEC 62109
TC
Thermal Cycling
500 cycles a 1h, -40°C – 85°C
IEC 60068-2-14
TH
Temperature Humidity
85°C, 85% RH, 1000h, passive and at high
voltage
IEC 60068-2-67
BST
Burst
Power terminals: 4kV; Control terminals: 2kV IEC 61000-4-4
CC
Climate Change
-15°C to 85°C; 10% to 85%; 10 cycles a 8h
IEC 60068-2-30
ESD
ESD
Contact discharge: 6kV; Air discharge: 8kV
IEC 61000-4-2
RFF
Radio Frequency
80 MHz – 1GHz, 20 V/m, 80% AM 1kHz
IEC 61000-4-3
RFD
RF Conducted Disturbance
150 kHz - 80 MHz, 20 V/m, v+h, 80 % AM
1kHz
IEC 61000-4-6
VB
Vibration
Sinusoidal 20Hz ... 500Hz, 5g
26 Sweeps per axis (x, y, z)
Random 10Hz … 2000Hz 3g
2 h per axis (x, y, z)
IEC 60068-2-6
SH
Shock
Half-sinus pulse, 30g, 6000 shocks, 11ms,
±x, ± y, ± z
IEC 60068-2-27
1
The test conditions are not the maximum applicable conditions for the products. The characteristics of the products are indicated in the
data sheet