© by SEMIKRON / 2019-07-23 / Technical Explanation / SKYPER
®
42 LJ R
PROMGT.1026/ Rev.7/ Template Technical Explanation
Page 31/35
8.
Environmental conditions
Table 11: SKYPER
42 LJ R | Environmental conditions
Insulation parameters
Rating
Grid voltage
690V
Climatic Classification Pollution Degree (PD)
PD2
Maximum altitude (above sea level)
2000 meter above sea
Overvoltage category (according to EN50178)
OVC 3
Isolation resistance test, Prim-Sec
4000 V AC rms, 60s
Rated insulation voltage (EN60664-1)
8 kV Cat. III
Creepage/clearance distance primary/secondary side
12.2mm
Creepage/clearance distance secondary/secondary side
6.1mm
Climate class
3K3 – IEC 60721-3-3
Environmental Condition
Norm / Standard
Operating/storage temperature
-40.. +85 °C
High humidity
85 °C, 85%
Flammability
UL94 V0
Heavy flammable materials only
RoHS / WEEE / China RoHS
EMC Condition
Norm / Standard
Parameter
ESD
DIN EN 61000-4-2
DIN EN 61800-3
6 kV contact discharge /
8 kV air discharge
Burst
DIN EN 61000-4-4
DIN EN 61800-3
≥ 2kV on adaptor board for signal lines
Immunity against external
interference
DIN EN 61000-4-3
DIN EN 61800-3
≥ 30V/m
30MHz – 1000 MHz
Immunity against conducted
interference
DIN EN 61000-4-3
DIN EN 61800-3
≥ 20V
150kHz – 80MHz
Shock Vibration
Vibration
Sinusoidal 20Hz … 500Hz, 5g, 2h per axis (x, y, z)
Random 20Hz … 2000Hz, 5g, 2 h per axis (x, y, z)
Shock
1000 Shocks (6 axis; +-x, +-y, +-z, 1000 shocks per axis), 30g, 18ms
Connection between driver and PCB has to be reinforced by support
post