© by SEMIKRON / 2019-07-23 / Technical Explanation / SKYPER
®
42 LJ R
PROMGT.1026/ Rev.7/ Template Technical Explanation
Page 30/35
7.
Product Qualification
Table 9: SKYPER
®
42 LJ R | Routine tests
test
test category
test description
Standard
AOI
Automated
Opt. Inspection
Control of accurate placement of
components/ of solder joints, 100%
SEMIKRON
ICT
In-Circuit Test
Test of the populated PCB, checking the
correctly fabrication, 100%
SEMIKRON
FAT
Function Test
Supply current, gate on/off, UVP, error,
100%
SEMIKRON
Table 10: SKYPER
®
42 LJ R | Approval tests
test
test category
test description
1
Standard
EP
Electrical Parameters
amb = -40°C / +85°C
SEMIKRON
ST
STEP Test
20x 10µs to 2s interruption
EN61000-4-29
ISO
Isolation
4.0 kV AC rms, 60s
EN50178
TC
Thermal Cycling
1000 cycles a 1h, Tstgmax – Tstgmin
IEC60068-2-14
TH
Temperature Humidity
85°C, 85% RH, 1000h
IEC60068-2-67
TS
High/Low Temp Storage
105°C/1000h; -40°C/1000h
IEC60068-2-2/1
BST
Burst
Power terminals: 4kV; Control terminals: 4kV EN61000-4-4
CC
Climate Change
-15°C to 85°C; 10% to 85%; 10 cycles a 8h
EN60068-2-30
HT
High Temp Operation
95°C, 500h, full load
SEMIKRON
ESD
ESD
Contact discharge: 6kV; Air discharge: 8kV
EN61000-4-2
RFF
Radio Frequency
80 MHz – 2.7GHz, 30 V/m, 80% AM 1kHz
EN61000-4-3
RFD
RF Conducted Disturbance
150 kHz - 80 MHz, 20 V/m, v+h, 80 % AM
1kHz
EN61000-4-6
VB
Vibration
Sinus 20/2000Hz Random 10/2000Hz, 5g, 26
per x,y,z
IEC 60068-2-6
SH
Shock
Half-sinus pulse, 30g, 6000 shocks, 6ms, ±x,
± y, ± z
IEC 60068-2-27
1
The test conditions are not the maximum applicable conditions for the products. The characteristics of the products are indicated in the
data sheet