SELVAS Healthcare Accuniq BC310 Скачать руководство пользователя страница 1

 

English. 06/2021. V3.02 

 

User Manual BC310 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Accuniq BC310

Страница 1: ...English 06 2021 V3 02 User Manual BC310...

Страница 2: ...ice Directive 93 42 EEC THE PERSONS RESPONSIBLE FOR PLACING DEVICES ON THE EC MARKET UNDER MDD 93 42 EEC SELVAS Healthcare Inc 155 Sinseong ro Yuseong gu Daejeon 34109 Republic of Korea TEL 82 42 879...

Страница 3: ...er supply and the scale cable 25 Leveling 25 Peripheral Device Installation 26 Connecting PC 26 Connecting Printer Option 27 Connecting EXTERNAL DEVICE 27 Replacing Thermal Paper 28 The trouble shooti...

Страница 4: ...nitor Software Program 47 RESULT INTERPRETATION 48 STORAGE MAINTENANCE 52 ERROR REPAIR 54 Kinds of Error Repair 54 Error occurrence Repair 55 AFTER SERVICE 57 AFTER SERVICE 57 How to contact SELVAS He...

Страница 5: ...s segmental analysis etc Intended application location is professional healthcare facility environments not home healthcare environment WORD DEFINITIONS To ensure safe operation and long term performa...

Страница 6: ...unity by standard of IEC 60601 1 2 2014 Electromagnetic Compatibility Requirements SAFETY PRECAUTIONS This device is designed and manufactured with consideration of the safety of the operator and subj...

Страница 7: ...e attached systems should be those certified by IEC 950 or equivalent standards for data processing equipment Configurations shall comply with the system standard IEC 60601 1 2005 A1 2012 Everybody wh...

Страница 8: ...a sufficient distance from such devices or turn them off Prohibition Do not disassemble or alter the device under any circumstances as this could result in electric shock or injury as well as adversel...

Страница 9: ...devices which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receivi...

Страница 10: ...ed in the replacement cartons to be shipped off from you to SELVAS Healthcare Shipping and insurance costs for return of defective unit must be prepaid by the users SAFETY SYMBOLS AND INFORMATION The...

Страница 11: ...Identifies the point where the safety ground of the system is fastened to the chassis Do not open This is for factory only Alternating current Direct current Date of manufacture Manufacturer Non ioniz...

Страница 12: ...cified IEC 60601 1 2 2014 Fourth Edition 2 Guidance and manufacturer s declaration electromagnetic immunity The ACCUNIQ BC310 is intended for use in the electromagnetic environment specified IEC 60601...

Страница 13: ...o assess obesity but the key factor in obesity assessment is the amount of fat accumulated in the body In general obesity is defined as the state of not only excessive weight compared with height visi...

Страница 14: ...eral fat to subcutaneous fat ratio is 0 4 and over the waist to hip ratio W H R is over 0 9 male 0 85 female the circumference of waist is over 102 cm 45 inches male _ 88 cm 35 inches female Visceral...

Страница 15: ...H PART Basic Package ACCUNIQ BC310 For whole body Column Head Part Weight scale Base part User manual Data management program USB cable Serial cable Power cable and adapter Thermal printer Roller The...

Страница 16: ...T ACCUNIQ BC310 For upper body Head Part Weight scale Base part User manual Data management program USB cable Serial cable Power cable and adapter Thermal printer Roller The model or specification are...

Страница 17: ...7 ACCUNIQ BC310 For lower body Head Part Weight scale Base part User manual Data management program USB cable Serial cable Power cable and adapter Thermal printer Roller The model or specification are...

Страница 18: ...dicates the measurer s blood pressure 2 Automatic Blood Pressure Monitor If SELVAS s automatic blood pressure monitor for hospital is connected to this device the measurer can easily check his her blo...

Страница 19: ...ual BC310 TERM AND FUNCTION OF EACH PART_19 5 Column It attaches to the head part with base part Main Body Front Part ACCUNIQ BC310 For whole body upper body Thermal printer Handle Electrode LCD scree...

Страница 20: ...h the hands during measurement Keypad The keypad consists of the function keys ZERO RESET CLOTH WEIGHT WEIGHT ONLY kg lb ON OFF 0 to 9 Alphabet MALE FEMALE Print CE BACK NEXT and the numeric button Th...

Страница 21: ...Rear Part SCLAE port Connecting the scale EXTERNAL DEVICE port Connecting External device manufactured by SELVAS Healthcare Inc PC port Connecting a computer ADAPTER port Connecting the adapter Note...

Страница 22: ...ectrodes and it measures weight Plate electrode It measures the impedance The user should step it in bare feet ACCUNIQ BC310 For upper body Weight scale It consists of four plate electrodes and it mea...

Страница 23: ...T It adjusts the scale to 0 point CLOTHES WEIGHT The user can input the weight of the clothes 0 5 5kg 0 9 9lbs WEIGHT ONLY It allows the device to operate in scale mode Press the button for 2sec It wi...

Страница 24: ...ric Keys CE button Numeric Keys are used for entering personal data Height Age The input data can be deleted by CE button BACK NEXT It moves forward backward to the next previous step during the Syste...

Страница 25: ...upply and the scale cable Connect the adapter to the adapter port placed on the rear panel of this device After the cables are connected to each port turn on the power switch on the keypad Leveling 5...

Страница 26: ...ual in the supplied USB memory Note 3 In order to save search and retrieve the users data the user should connect the BCA to a computer with our free data management software installed Printing is don...

Страница 27: ...s placed on the rear panel of the device Connect the printer to the PC with printer cable The result sheet can be printed out from the printer Connecting EXTERNAL DEVICE EXTERNAL DEVICE can be connect...

Страница 28: ...the upper printer cover 3 Put the roller into the center hole of the thermal paper 4 Insert the thermal paper with the roller into the holder as shown in the picture 5 Take the edge of the paper out...

Страница 29: ...User Manual BC310 INSTALLATION_29 9 Press the Jam button located inside the printer 10 Remove the jammed paper...

Страница 30: ...SETUP of this device can be changed for improvement Entering SYSTEM SETUP At initial display press 1 2 3 4 button in keypad to enter SYSTEM SETUP screen Menu in SYSTEM SETUP The function of each menu...

Страница 31: ...STEM SETUP screen appears Exiting SYSTEM SETUP Press BACK button on SYSTEM SETUP screen The initial screen appears Setup DATE TIME This is to set date and time year month day hour and minute Select DA...

Страница 32: ...rns to the previous setting and SYSTEM SETUP screen appears 2 When manager program is used in data management measured date is automatically saved as the date set in this device Therefore the date and...

Страница 33: ...3 Adjust the brightness by pressing and on the screen Press NEXT button to save the setting Press BACK button to return to SYSTEM SETUP screen BACKLIGHT It adjusts the backlight of the screen Default...

Страница 34: ...ing and button Press NEXT button in keypad Pre set NO Choose YES or NO by pressing and button in keypad If YES is chosen abdominal analysis is displayed to all age If NO is chosen abdominal analysis i...

Страница 35: ...M SETUP screen by pressing BACK button in keypad Note It has no Goal setter in the ACCUNIQ BC310 For upper body lower body DATE TYPE This is to set the format of the date Select DATE TYPE on SYSTEM SE...

Страница 36: ...und with and button on keypad Press NEXT button in keypad to save selected value Return to SYSTEM SETUP screen by pressing BACK button in keypad THERMAL PRINT It selects the printing mode of thermal p...

Страница 37: ...TYPE or VERTICAL TYPE THERMAL LOGO It choose whether using thermal logo Select THERMAL LOGO on SYSTEM SETUP screen by pressing and button Press NEXT button in keypad Choose ON or OFF by pressing and...

Страница 38: ...a stable condition Measure 3 4 hours after a bath a sauna exercise or activity that causes a lot of sweating Or measure before these activities 3 Avoid drinking alcohol 24 hours before the measurement...

Страница 39: ...and activities exercise sauna drinking lots of beverage urination etc are kept same the reproducibility of a device is obtained Therefore the data can be used to evaluate the change of body compositio...

Страница 40: ...erfectly touched during measurement measurement will be stopped or the result is not reliable Measuring Posture Step the scale in the bare feet Stretch both arms and spread them 30 from the body Press...

Страница 41: ...ured weight is displayed on the screen 2 After the weight measurement input the personal data 3 Personal information Input the following information in a order gender age and height Confirm input data...

Страница 42: ...al P B F using the numerical buttons on the keypad The possible input range is 3 30 Press the NEXT button Note When you set OFF Goal setter this screen will not be displayed 4 Measurement posture Once...

Страница 43: ...ted result sheet After confirming the result press NEXT button if you want to measure again The device returns to the initial screen after one minute Note 1 If Automatic printing is selected at SYSTEM...

Страница 44: ...ther MALE or FEMALE from the keypad Input age The following message appears Input your age Input age using the numerical buttons on the keypad Press NEXT button Input height The following message appe...

Страница 45: ...results and press PRINT or NEXT button ACCUNIQ BC310 For lower body 1 Weight measurement When the subject steps on the scale the screen changes with a chime bell Do not move or speak until the measure...

Страница 46: ...ppears Input your age Input age using the numerical buttons on the keypad Press NEXT button Input height The following message appears Input your height Input height using the numerical buttons on the...

Страница 47: ...ocedure is as follows 1 Connect a Blood Pressure Monitor to the device 2 Connect the device to a computer in which manager program is installed 3 Turn on the power of BPM and the computer Turn on the...

Страница 48: ...tracting mass of body fat from body weight Lean body mass consists of fat free mass of body such as muscle organs blood and water 4 S L M Soft Lean Mass It composes of body water and protein 5 Mineral...

Страница 49: ...l overweight obese 18 5 18 5 25 25 30 over 30 3 Obesity degree Indicates the degree of obesity of the current weight against the standard weight Fatness current weight Standard weight Standard weight...

Страница 50: ...Comprehensive Evaluation 1 Body Type Body type is determined by B M I and P B F Body type is classified into 9 types Thin fat Low Weight Low fat Low weight Over fat Standard Low fat muscular Obese Ove...

Страница 51: ...ommended weight 7 Setting Goal Input a goal Body fat It provides goal weight goal P B F Body Fat to be controlled When you input 0 goal Body Fat will not be printed 1 Goal weight It indicates a goal w...

Страница 52: ...ion Do not splash any fluid on this device or insert any foreign substances In case of inserting foreign substances or exposing to particular environment this device must be examined by an expert befo...

Страница 53: ...lution Then wipe the enclosure with a soft lint 2 Please refer to and abide by the SAFETY PRECAUTIONS Caution Users must be sure to use sterile safety equipment such as gloves when in contact with or...

Страница 54: ...s neither something with wrong input of personal data age gender nor with measuring error of weight and impedance try again It can t measure if the P B F is out of range When the same error occurs eve...

Страница 55: ...cut blade is shown outward Open the cover of Printer Cut Turn the plastic Phillips head screws clockwise and push the blade back If the problem remains please contact SELVAS Healthcare or its local di...

Страница 56: ...k even when start buttons are correctly pressed Defective cable between the head and the scale Start buttons are defective Contact SELVAS Healthcare or its local distributor where this device is purch...

Страница 57: ...tion which will assist your appropriately qualified technical personnel to repair those parts of unit which are designated by SELVAS Healthcare as repairable How to contact SELVAS Healthcare Write us...

Страница 58: ..._AFTER SERVICE 2 Turn off the power of the peripheral devices and disconnect all cables 3 Disassemble the device in reverse order of assembly 4 Pack the device with the original packing materials 5 Tr...

Страница 59: ...egs and trunk Body Type Ratio of E C W T B W Basal Metabolic Rate Impedance Target PBF Predicted weight predicted MBF Control Weight Standard weight Mass of Body Fat Lean Body Mass Total Body Water In...

Страница 60: ...0 Measuring time Within 1 minute Input height 50 220 cm Measuring weight 10 200 kg Applicable age 1 99 years old Operation ambient Temperature 5 40 Humidity 15 93 non condensing Storage ambient Temper...

Страница 61: ...eriod of warranty Within 1 year from the date of manufacture Date of purchase Customer Add Name Tel Dealer market Add Name Tel Note When you receive this warranty make sure that the name of the dealer...

Страница 62: ...ck Mainframe 1 Keys Smooth operation Pass Fail 2 Recorder Smooth operation with no abnormal sound Pass Fail 3 Touch Screen Smooth operation Pass Fail Accessories 1 Power cord Smooth operation and remo...

Страница 63: ...me 1 Touch Screen Smooth operation Pass Fail 2 Recorder Smooth operation with no abnormal sound Pass Fail Accessories 1 Power cord Smooth operation and removal Pass Fail Electrical Check Performance 1...

Страница 64: ...2 864 4462 If the problems continue call the service center When you ask for service the manufacturer s label serial number date of original purchase and explanation of malfunction will be required Se...

Отзывы: