5-28
5
TIP:
• When measuring the output peak voltage
under the cranking condition, remove the
clip from the engine shut-off switch to pre-
vent the engine from starting.
• When measuring the output peak voltage
under the unloaded condition, disconnect
the special service tool coupler
b
.
• When pulling the starter handle to crank the
engine, the voltage values may vary
depending on the speed at which the
starter handle is pulled. (Manual starter
model)
4.
Measure the lighting coil resistance.
5.
Remove the special service tool
1
, and
then connect the lighting coil coupler.
6.
Install the manual starter. See “Installing
the manual starter” (7-10). (Manual
starter model)
Install the flywheel magnet cover. (Elec-
tric starter model)
Checking the Rectifier Regulator
(electric starter model)
Before checking the Rectifier Regulator,
make sure to check the lighting coil.
If the battery cables are connected in
reverse, the Rectifier Regulator can be
damaged.
1.
Remove the flywheel magnet cover.
2.
Slide the grommet
a
away from the Rec-
tifier Regulator coupler
b
.
3.
Measure the Rectifier Regulator output
peak voltage.
TIP:
• Measure the Rectifier Regulator output
peak voltage with the coupler
b
con-
nected.
• Do not use peak voltage adapter B measur-
ing the Rectifier Regulator output peak volt-
age.
4.
Fit the grommet
a
into the Rectifier Reg-
ulator coupler
b
.
5.
Disconnect the Rectifier Regulator cou-
plers.
6.
Check the Rectifier Regulator for conti-
nuity. Replace if out of specification.
Lighting coil resistance (reference data):
0.21–0.29
Ω
at 20 °C (68 °F)
Rectifier Regulator output peak voltage:
Red (R)–Ground
r/min
Loaded
1500
3500
DC V
13.0
13.0
B
R
G
G
B
R
b
a
B
R
b
Содержание Kingfish 25
Страница 1: ...YAMAHA MOTOR CO LTD F4A F4 Goldfish 4 Kingfish 25 SERVICE MANUAL...
Страница 4: ......
Страница 20: ...0 15 GEN INFO General information MEMO...
Страница 45: ...1 25 SPEC Specification MEMO...
Страница 65: ...2 19 TECH FEA Technical features and description MEMO...
Страница 81: ...3 17 RIG GING Rigging information MEMO...
Страница 215: ...7 67 POWR Power unit MEMO...
Страница 229: ...LOWR Lower unit 8 11 0 A...
Страница 242: ...8 24 8 Shimming Shim location T1 T2 T3 T3 A3 B3 42 5 T1 T2 24 0 24 0 B2 A1 A2 B1 Drive shaft and lower case Shimming...
Страница 259: ...LOWR Lower unit 8 41 5 Install new O rings C and D Ball bearing attachment B 90890 06633 A G B C D...
Страница 392: ...A Appendix Wiring diagram A 1 How to use the wiring diagram A 1...
Страница 394: ......
Страница 395: ......