PRINTER INSTALLATION  

HOW TO GUIDE

OP-412T

OP-412T-L1

OP-412T-L2

OP-900 / OP-901 Indicator Parameter Settings

To enter calibration/parameter settings, follow the procedure below:

1.

Make sure the unit is set to either kg or lb

2.

Press and hold the HOLD and PRINT key at the same time for 2 seconds

3.

Navigate through the settings (C01 to C18) as shown in the table below by using the arrow keys and return keys as labeled under
each indicator button

4.

Press the PRINT

 key to enter/edit the parameter setting

5.

Press the ACCUM key to save and exit settings at any time

Function

Parameter Settings/Options

Communication 

Setting

C18

Set the serial interface data output method:

0 = Turn off serial interface data output

1 = Continuous sending mode, for remote display

2 = Print to paper thermal ticket printer (OP-412T)

3 = Command request mode, for computer.

4 = PC continuous sending mode, for computer

5 = PC/remote display, continuous sending mode

6 = Print to small label thermal printer (OP-412T-L1)

7 = Print to Zebra/large label thermal printer (OP-412T-L2)

8 = Reserved

Baud Rate

C19

0 = 1200 (for OP-910 remote display)

1 = 2400

2 = 4800

3 = 9600 (for all Printers and OP-910X, OP-910XL)

4 = 14400

S E L L E T O N   S C A L E S

2 5 5 7 0   R Y E   C A N Y O N   R D ,   U N I T   H

S A N T A   C L A R I T A ,   C A   9 1 3 5 5

8 4 4 . 7 3 5 . 5 3 8 6   |   I N F O @ S E L L E T O N S C A L E S . C O M

[email protected]

WWW.SELLETONSCALES.COM

25570 Rye Canyon Rd Unit H, Santa Clarita, CA 91355, United States

844-735-5386

S E L L E T O N   S C A L E S

Отзывы: