background image

Doc. name: OP INST RPS240-24-CE OP891-V02(Page 1 of 2)

WIRING INSTRUCTIONS

1. To prevent risk of electric shock, power supply equipment must be

kept OFF while wiring.

2. Terminals and electrically charged parts must not be touched when

the power is ON.

3. Wiring shall be done strictly according to terminal layout provided

in the operating manual.

50*136*135mm  (W*H*D)

645 gms

DIMENSIONAL DIAGRAM

DIMENSION

WEIGHT

OP891-V02

PROTECTIONS

OUTPUT OVER VOLTAGE

OVER TEMPERATURE

110% to 140% of rated output current
Protection type : Hiccup mode; recovers
automatically after fault condition is removed.

31VDC
Protection type :

± 0.5VDC

Latched; Input AC power

has to be recycled to recover the power supply.

Power supply shuts down when the temperature of PCB
below PFC choke reaches typically 120 C; Recovers
automatically when temperature falls to typically 90 C.

0

0

4A - 250VAC Internal

Hiccup mode when output is shorted; Recovers
automatically after fault condition is removed.

INPUT FUSED

OUTPUT SHORT CIRCUIT

OUTPUT OVER LOAD

Ø

Ø

Ø

Ø

Ø

Ø

AC 100-240V Wide-range Input.
Active PFC
Cost optimized without compromising quality or reliability.
Full power between -25 C and +50

.

DC-OK Relay contact.
Compact size.

0

0

C

FEATURES

SPECIFICATION

RPS240-24-CE

Operating Instruction

selec

WIRING  DIAGRAM

50

136

135

5

INTENDED USE

This device is designed for installation in an enclosure and is intended for the
general professional use such as in

ndustrial control

communication .

Do not use this power supply in equipment where malfunction may cause
severe personal injury or threaten human life.

instrumentation equipment, office,

i

and

SAFETY INSTRUCTION

PE (Protective

Earth) Input

OUTPUT SPECIFICATIONS

25ms at 24V & 16ms at 28V @ 115/230VAC, Full Load

HOLD UP TIME

24 - 28VDC

<1% of Vout

10A at 24V; 8.6A at 28V

OUTPUT VOLTAGE
OUTPUT CURRENT

RIPPLE AND NOISE

LINE AND LOAD REGULATION

±1%

Possible for up to two power supplies
(with external diode)

*

DC-OK CONTACT

SERIES OPERATION

30VDC 1A; 60VDC 0.5A; 125VAC 0.5A,

resistive load; min. current 1mA

24VDC 10A

OUTPUT

L N

DC ON

DC ON

Vo ADJ.

DC OK

DC OK

+

-

-

+

100 - 240VAC

; 50/60Hz

100 - 240VAC

; 50/60Hz

INPUT

INPUT

RPS240-24-CE

240W

ENVIRONMENT

STORAGE TEMPERATURE

ALTITUDE

-40 C to +85 C.

0

0

2000m

-25 C to +70 C
*De-rate output power at 6W/ C above +50 C Ambient.

0

0

0

0

5 to 95% RH, Non Condensing

OPERATING TEMPERATURE

HUMIDITY

CURRENT HARMONICS

Class D

EMS IMMUNITY

Compliance to IEC61000-4-4,5,11

EN55022 ; Class A

RADIATED EMISSION

EN55022 ; Class B

CONDUCTED EMISSION

SAFETY & EMC

DIELECTRIC WITHSTAND
VOLTAGE

I/P to Earth       : 2500VAC
I/P to O/P

: 4000VAC

O/P to Earth

: 1500VAC

O/P to DC-OK  : 500VAC

Designed to meet IEC 62368-1
Processing for UL-508

SAFETY STANDARDS

100 M   min. (between all outputs and all inputs

terminals) at 500 VDC

/

PE

INSULATION RESISTANCE

Ω

INPUT SPECIFICATIONS

100 - 240VAC

INPUT VOLTAGE RANGE

START UP TIME

AC CURRENT(TYP.)

2.4A @ 115VAC; 1.2A @ 230VAC

EFFICIENCY(TYP.)

93% @ 230VAC

INRUSH  CURRENT(TYP.)

<60Amps; Measured at  264VAC,
25 C Ambient, Cold Start

0

POWER FACTOR

>0.95 @ Full Load Over entire input range

2 Sec @ Full Load Over entire input range

FREQUENCY RANGE

50-60Hz

±10% ; 127 - 370VDC

<