Seifert KG 4555-120V Скачать руководство пользователя страница 1

Version Nr. 25 - 29.10.2016

Doc. Nr. 9945551001

1 / 19

Table of Content KG 4555-120V

1. User manual 

 2

 ................................................................................................................... 

2. Legal regulations 

 2

 ........................................................................................................... 

3. Safety instructions 

 3

 ........................................................................................................ 

4. Technical information 

 4

 ................................................................................................... 

5. Functional principle 

 4

 ...................................................................................................... 

6. Technical data 

 5

 ................................................................................................................ 

7. Performance Graph 

 6

 ....................................................................................................... 

8. Mounting 

 7

 ......................................................................................................................... 

9. Mounting Principle 

 8

 ........................................................................................................ 

10. Cut out dimensions 

 9

 ..................................................................................................... 

11. Dimensions (H x W x D) 

 10

 ............................................................................................ 

12. Electrical connection 

 11

 ................................................................................................. 

13. Controller Layout Description 

 13

 ................................................................................. 

14. Wiring diagram 

 14

 .......................................................................................................... 

15. Taking into operation 

 15

 ............................................................................................... 

16. Repair  

 16

 ......................................................................................................................... 

17. Maintenance & Cleaning 

 16

 .......................................................................................... 

18. Maintenance 

 17

 ............................................................................................................... 

19. Transport & Storage 

 18

 ................................................................................................. 

20. Parts supplied 

 19

 ............................................................................................................ 

 

Содержание KG 4555-120V

Страница 1: ...Functional principle 4 6 Technical data 5 7 Performance Graph 6 8 Mounting 7 9 Mounting Principle 8 10 Cut out dimensions 9 11 Dimensions H x W x D 10 12 Electrical connection 11 13 Controller Layout...

Страница 2: ...instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a specific pictogram such as one of the following High electric voltage Indicates...

Страница 3: ...ds to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid safety regulati...

Страница 4: ...bient conditions e g dusty and oily air The operating temperature range is between 20 C and 55 C Units can be ordered with an additional electrical cabinet heater For the cooling capacities and eviron...

Страница 5: ...erature range 10 C 55 C Air volume flow Ambient air circuit 360 m h Cabinet air circuit 720 m h Mounting Roof mounted Material housing Mild steel powder coated Dimension HxWxD 400 x 400 x 600 mm Weigh...

Страница 6: ...Version Nr 25 29 10 2016 Doc Nr 9945551001 6 19 7 Performance Graph T Ambient temperature P Cooling capacity...

Страница 7: ...t partially or completely blocked by obstructions in the cabinet Sealing To guarantee that the unit works perfectly ensure that the control cabinet is completely sealed to min IP54 according to EN 605...

Страница 8: ...t on the cabinet Set the unit up on the cabinet Screw the M6 hex head screws together with the washers and locking washers into the M6 threaded rivets in the uni The resistance of the earth connection...

Страница 9: ...Version Nr 25 29 10 2016 Doc Nr 9945551001 9 19 10 Cut out dimensions...

Страница 10: ...Version Nr 25 29 10 2016 Doc Nr 9945551001 10 19 11 Dimensions H x W x D...

Страница 11: ...r lamps switches The load on these contacts is not to exceed 30V AC DC 5 A If wired to external components it must be ensured that the wiring and connections are double insulated and safe against touc...

Страница 12: ...n be switched on or off via a door contact switch terminal T1 T2 When delivered the door contact terminals are bridged To connect the door contact switch Remove the bridge from terminals T1 T2 Connect...

Страница 13: ...oc Nr 9945551001 13 19 13 Controller Layout Description C1 2 3 Fan capacitors C Connection terminals M Mikrocontroller Alarm Potentiometer alarm temperature Temp Potentiometer cabinet temperature T Tr...

Страница 14: ...arth connector R11 Control temperature potentiometer R12 Alarm temperature potentiometer 1 L1 Live 4 N Neutral PE Earth 6 P1 Alarm contact 7 P2 Alarm contact Normal with power ON Alarm with power ON 8...

Страница 15: ...PC board slightly to the right higher or to the left lower Close the unit in the prescribed manner Check that the new adjusted values meet the necessary requirements If necessary repeat the procedure...

Страница 16: ...y The control cabinet needs re sealing Fan or fan capacitor on the cold side are faulty Replace fan and or fan capacitor Too much condensate Cabinet door not closed Ensure that cabinet door is closed...

Страница 17: ...be used Danger from electrical voltage The unit must be removed from the control cabinet for wet cleaning Instruction Never use aggressive cleaning fluids or materials Should fluid cleaning be necessa...

Страница 18: ...ction due to transport damage On delivery the carton box containing the unit must be examined for signs of transport damage Any transport damage to the carton box could indicate that the unit itself h...

Страница 19: ...ms Ltd Seifert Systems AG Seifert Systems Inc Seifert Systems Pty Ltd Ha linghauser Str 156 HF09 10 Wilerstrasse 16 75 Circuit Drive 105 Lewis Road Hal Far Industrial Estate North Kingstown Wantirna S...

Отзывы: