Seifert 87060082USL Скачать руководство пользователя страница 1

Version Nr. 1-5 - 25.07.2022

Doc. No. 9987060082USL

1 / 22

Table of Content 87060082USL

1. User manual 

2

 .................................................................................................................................. 

2. Legal regulations 

2

 ......................................................................................................................... 

3. Safety instructions 

3

 ...................................................................................................................... 

4. Settings 

4

 ......................................................................................................................................... 

5. Functional principle 

5

 ..................................................................................................................... 

6. Technical data 

6

 .............................................................................................................................. 

7. Performance graph 

7

 ...................................................................................................................... 

8. Mounting 

8

 ....................................................................................................................................... 

9. Condensate management 

9

 ........................................................................................................... 

10. Mounting Principle 

10

 .................................................................................................................. 

11. Cut out dimensions 

11

 .................................................................................................................. 

12. Dimensions (H x W x D) 

12

 .......................................................................................................... 

13. Electrical connection 

13

 ............................................................................................................... 

14. Controller 

14

 .................................................................................................................................. 

15. Wiring diagram 

18

 ......................................................................................................................... 

16. Taking into operation 

19

 .............................................................................................................. 

17. Trouble shooting 

19

 ...................................................................................................................... 

18. Maintenance & Cleaning 

20

 ......................................................................................................... 

19. Transport & Storage 

21

 ................................................................................................................ 

20. Parts supplied / Spare parts / Accessories 

22

 .......................................................................... 

 

Содержание 87060082USL

Страница 1: ...ple 5 6 Technical data 6 7 Performance graph 7 8 Mounting 8 9 Condensate management 9 10 Mounting Principle 10 11 Cut out dimensions 11 12 Dimensions H x W x D 12 13 Electrical connection 13 14 Contro...

Страница 2: ...instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a speci c pictogram such as one of the following High electric voltage Indicates...

Страница 3: ...ad with regards to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid sa...

Страница 4: ...separate air circuits which ensure that the clean cabinet air does not come into contact with the ambient air which may well be dirty or polluted Enclosure cooling units can dissipate large quantities...

Страница 5: ...nt thus taking it to high pressure and high temperature and pushes it through the condenser where it is cooled by ambient air thus passing from the gas to the liquid state At the liquid state it then...

Страница 6: ...impeded Ambient 140 240 cfm Cabinet 70 105 cfm Mounting Wall mounted Housing Material Mild steel powder coated Dimension H x W x D 15 x 9 85 x 9 85 inch Weight 35 lbs Voltage Frequency 230 V 50 60 Hz...

Страница 7: ...Version Nr 1 5 25 07 2022 Doc No 9987060082USL 7 22 7 Performance graph...

Страница 8: ...e cut packaging opening facing up STEP 2 Pull o the packaging opening STEP 3 Hang the transport loop of the unit in the transport hook and lift it slightly STEP 4 Pull o the packaging and slide out th...

Страница 9: ...by storage conditions please check this template by verifying values of the largest dimensions before drilling Fit the sealing strip on the cooling unit on the side connected to the enclosure and fol...

Страница 10: ...within the rst 15 minutes after installation Use only the supplied mounting hardware Tighten Screws to 4 5 Nm Ensure the mounting surface does not warp after assembly and reinforce it if necessary 1 M...

Страница 11: ...Version Nr 1 5 25 07 2022 Doc No 9987060082USL 11 22 11 Cut out dimensions...

Страница 12: ...Version Nr 1 5 25 07 2022 Doc No 9987060082USL 12 22 12 Dimensions H x W x D...

Страница 13: ...if closed Door contact terminals bridged or NC door switch connected contact must be closed when cabinet door is closed c68 1 ON if open Remove bridge or NO door switch connected contact must be open...

Страница 14: ...ress 2 Alarm relay active 3 Heater relay active 4 Ambient blower relay active Alarm Flashes when alarms are active Heating mode Signals operation of unit in heating mode Cooling mode Signals operation...

Страница 15: ...e C 0 F 1 P25 for low temperature alarm threshold default 10 C 14 F P26 for high temperature alarm threshold default 55 C 131 F c68 for door contact NO NC logic change 0 ON if closed 1 ON if open Cont...

Страница 16: ...with an icon ashing triangle alternating with the standard display If more than one error occurs these are shown in sequence on the display Failure Code Description Solution OFF Door open Close the en...

Страница 17: ...button for at least 5 seconds When pressing PRG for 3 seconds the rmware revision code is displayed for 2 seconds When cleaning the controller panel do not use ethanol hydrocarbons ammonia or their by...

Страница 18: ...Version Nr 1 5 25 07 2022 Doc No 9987060082USL 18 22 15 Wiring diagram Power Cable AWG18 BK L1 BU N GNYE PE Signals Cable AWG20 GY Alarm NC BN Alarm COM BU Alarm NO RD Door contact PK Door contact...

Страница 19: ...sor don t work Enclosure temperature is below setting temperature St Verify values of parameter St Door switch contact is open Verify door switch Controller doesn t work Replace controller Internal fa...

Страница 20: ...d be replaced immediately Do not use a steam jet or high pressure to clean the lter mats Do not wring out the lter mats If the ambient air is extremely oily we recommend the use of metal lters see acc...

Страница 21: ...temperature range 40 F to 158 F relative humidity at 77 F max 95 the air conditioner should always be stored according to the installation position Returning the unit To avoid transport damage the un...

Страница 22: ...s supplied Spare parts Accessories Description QTY Image Instruction manual 1 CE Declaration 1 Mounting template 1 M6 16 bolts 6 A6 4 toothed washers 6 A6 4 washers 6 Seifert Systems Inc 75 Circuit Dr...