Version No. 1-2 - 28.06.2022

Doc. No. 99850620S62

3 / 26

 

2. Legal regulations

Liability
The information, data and instructions contained in this instruction manual are current at the time of going to
press. We reserve the right to make technical changes to the unit in the course of its development. Therefore,
no claims can be accepted for previously delivered units based on the information, diagrams or descriptions
contained in this manual. No liability can be accepted for damage and production caused by:

Disregarding the instruction manual
Operating error
Inappropriate work on or with the unit
The use of non-specified spare parts and accessories
Unauthorised modifications or changes to the unit by the user or his personnel

The supplier is only liable for errors and omissions as outlined in the guarantee conditions contained in the main
contractual agreement. Claims for damages on any grounds are excluded.

Содержание 850620S62

Страница 1: ...ngs 5 5 Functional principle 6 6 Technical data 7 7 Performance graph 8 8 Mounting 9 9 Mounting Principle 13 10 Cut Out Dimension 14 11 Electrical Connection 15 12 Controller 16 13 Wiring Diagram 20 1...

Страница 2: ...issipation of heat from control cabinets and enclosures stationary not moving in order to protect temperature sensitive components in an industrial environment To meet the conditions of use all the in...

Страница 3: ...units based on the information diagrams or descriptions contained in this manual No liability can be accepted for damage and production caused by Disregarding the instruction manual Operating error In...

Страница 4: ...y regulations One can nd dangerous voltages above 50 V AC or above 100 V DC Behind the control cabinet doors On the power supply in the unit housing The unit has to be operated according to the type p...

Страница 5: ...does not come into contact with the ambient air which may well be dirty or polluted Enclosure cooling units can dissipate large quantities of heat from sealed enclosures such as electrical enclosures...

Страница 6: ...t thus taking it to high pressure and high temperature and pushes it through the condenser where it is cooled by ambient air thus passing from the gas to the liquid state At the liquid state it then p...

Страница 7: ...net air circuit 122 180 m h Mounting Wall mounted recessed Housing Material Stainless steel AISI 304 V2A Dimensions A x B x C D E 600 x 250 x 187 6 48 6 139 mm Weight 16 kg Voltage Frequency 400V 460...

Страница 8: ...Version No 1 2 28 06 2022 Doc No 99850620S62 8 26 7 Performance graph...

Страница 9: ...cut packaging opening facing up STEP 2 Pull o the packaging opening STEP 3 Hang the transport loop of the unit in the transport hook and lift it slightly STEP 4 Pull o the packaging and slide out the...

Страница 10: ...internal and external are not obstructed It must also be ensured in accordance with UL that the air outlet is not blowing air directly at an equipment operator Should this be the case a barrier or duc...

Страница 11: ...No 1 2 28 06 2022 Doc No 99850620S62 11 26 Cold air outlet duct When using a cold air outlet duct please follow the steps below Filter installation If you install replace a lter please follow the step...

Страница 12: ...cooling unit releases the condensate to the environment If too much condensation forms the condensation is drained out of the cooling unit from the front through the lower gill grilles If this hose i...

Страница 13: ...after installation Use only the supplied mounting hardware Tighten Screws to 4 5 Nm Ensure the mounting surface does not warp after assembly and reinforce it if necessary 1 M6 screws 2 M6 toothed wash...

Страница 14: ...Version No 1 2 28 06 2022 Doc No 99850620S62 14 26 10 Cut Out Dimension...

Страница 15: ...oller Setting temperature units C F low temperature alarm door contact logic section for more information c68 0 default ON if closed Door contact terminals bridged or NC door switch connected contact...

Страница 16: ...ess 2 Alarm relay active 3 Heater relay active 4 Ambient blower relay active Alarm Flashes when alarms are active Heating mode Signals operation of unit in heating mode Cooling mode Signals operation...

Страница 17: ...C 0 F 1 P25 for low temperature alarm threshold default 10 C 14 F P26 for high temperature alarm threshold default 55 C 131 F c68 for door contact NO NC logic change 0 ON if closed 1 ON if open Contr...

Страница 18: ...table The display shows either OFF or EXX with an icon ashing triangle alternating with the standard display If more than one error occurs these are shown in sequence on the display Failure Code Descr...

Страница 19: ...ase scrolling speed press and hold the or button for at least 5 seconds When pressing PRG for 3 seconds the rmware revision code is displayed for 2 seconds When cleaning the controller panel do not us...

Страница 20: ...Version No 1 2 28 06 2022 Doc No 99850620S62 20 26 13 Wiring Diagram Power connector 1 L1 2 Lx 3 L2 4 PE Signal connector 1 Alarm NC 2 Alarm COM 3 Alarm NO 4 Door contact 5 Door contact...

Страница 21: ...be protected with a MCB Type D or K Upon connection the internal fan will start working If the temperature inside the enclosure is higher than the set value of the controller both the compressor and e...

Страница 22: ...city Compressor and external fan work in alternating mode ON OFF Thermal compressor protector triggered Verify if ambient temperature is too high clean condenser Refrigerant leakage Contact dealer ser...

Страница 23: ...topper from in the base of the unit factory setting is locked 1 Dispose the plastic stopper but keep the Slilicon washer 2 Insert the drain socket 3 Lock it clockwise and x the oel cleaning pipe onto...

Страница 24: ...s Temperature range 40 C to 70 C Relative humidity at 25 C max 95 The cooling unit should always be stored according to the installation position Returning the unit To avoid transport damage the unit...

Страница 25: ...d Spare parts Accessories Description QTY Image Instruction manual 1 CE Declaration 1 Mounting template 1 M6 16 bolts 8 A6 4 toothed washers 8 A6 4 washers 8 5 pole terminal block for signals 1 4 pole...

Страница 26: ...External transformer 400 460 V 2 AC 8503 05 06 CS 1 Door switch contact 3100001 Seifert Systems GmbH Seifert Systems Ltd Seifert Systems AG Seifert Systems GmbH Seifert Systems Ltd Seifert Systems In...