12. Controller

The display shows the temperature in the range of -50°C to +150°C (-58°F to +302°F). The temperature is
displayed with resolution of tenths between -19.9°C and +99.9°C (-3.8°F to +211.8°F). During programming, it
shows the codes and values of the parameters. The display also shows icons according to occurring events.

Display icons

Icon Function

Description

   1

Compressor relay active

Flashes when activation is delayed or inhibited by
protection times, external disabling or other procedures 
in progress

   2

Alarm relay active

   3

Heater relay active

   4

Ambient blower relay active    
Alarm

Flashes when alarms are active

Heating mode

Signals operation of unit in heating mode

Cooling mode

Signals operation of unit in cooling mode

TEST Test mode in progress

Activated only by manual procedure

Programming
The operating parameters can be modified using the front keypad. Access differs depending on the type of
parameter.  Access to configuration parameters is protected by a password that prevents unwanted
modifications or access by unauthorised persons.

Setting cooling set point, St1:

1. Press “SET” and display should show St1 and then the pre-set value of St1. (default: +35°C / +95°F)
2. Reach the desired value by using ▲ or ▼.
3. Press “SET” again to save the new value of St1.

Содержание 84120001-BZBG

Страница 1: ...ettings 5 5 Functional principle 6 6 Technical data 7 7 Performance graph 8 8 Mounting 9 9 Mounting Principle 13 10 Cut Out Dimension 15 11 Electrical Connection 16 12 Controller 18 13 Wiring Diagram...

Страница 2: ...dissipation of heat from control cabinets and enclosures stationary not moving in order to protect temperature sensitive components in an industrial environment To meet the conditions of use all the...

Страница 3: ...d units based on the information diagrams or descriptions contained in this manual No liability can be accepted for damage and production caused by Disregarding the instruction manual Operating error...

Страница 4: ...ety regulations One can nd dangerous voltages above 50 V AC or above 100 V DC Behind the control cabinet doors On the power supply in the unit housing The unit has to be operated according to the type...

Страница 5: ...r does not come into contact with the ambient air which may well be dirty or polluted Enclosure cooling units can dissipate large quantities of heat from sealed enclosures such as electrical enclosure...

Страница 6: ...e refrigerant thus taking it to high pressure and high temperature and pushes it through the condenser where it is cooled by ambient air thus passing from the gas to the liquid state At the liquid sta...

Страница 7: ...uit 550 850 m h Enclosure air circuit 350 850 m h Mounting Wall mounted recessed Housing Material Mild steel powder coated Dimensions A x B x C D E 950 x 395 x 250 55 195 mm Weight 38 5 kg Voltage Fre...

Страница 8: ...Version No 1 5 09 11 2022 Doc No 9984120001 BZBG 8 28 7 Performance graph...

Страница 9: ...e cut packaging opening facing up STEP 2 Pull o the packaging opening STEP 3 Hang the transport loop of the unit in the transport hook and lift it slightly STEP 4 Pull o the packaging and slide out th...

Страница 10: ...t internal and external are not obstructed It must also be ensured in accordance with UL that the air outlet is not blowing air directly at an equipment operator Should this be the case a barrier or d...

Страница 11: ...1 5 09 11 2022 Doc No 9984120001 BZBG 11 28 Cold air outlet duct When using a cold air outlet duct please follow the steps below Filter installation If you install replace a lter please follow the st...

Страница 12: ...he cooling unit releases the condensate to the environment If too much condensation forms the condensation is drained out of the cooling unit from the front through the lower gill grilles If this hose...

Страница 13: ...s after installation Use only the supplied mounting hardware Tighten Screws to 4 5 Nm Ensure the mounting surface does not warp after assembly and reinforce it if necessary 1 M6 screws 2 M6 toothed wa...

Страница 14: ...Version No 1 5 09 11 2022 Doc No 9984120001 BZBG 14 28...

Страница 15: ...Version No 1 5 09 11 2022 Doc No 9984120001 BZBG 15 28 10 Cut Out Dimension...

Страница 16: ...troller Setting temperature units C F low temperature alarm door contact logic section for more information c68 0 default ON if closed Door contact terminals bridged or NC door switch connected contac...

Страница 17: ...2022 Doc No 9984120001 BZBG 17 28 Connect unit Connect the cooling device according to the instructions below The cable cross section must correspond to the required power for the current consumption...

Страница 18: ...gress 2 Alarm relay active 3 Heater relay active 4 Ambient blower relay active Alarm Flashes when alarms are active Heating mode Signals operation of unit in heating mode Cooling mode Signals operatio...

Страница 19: ...re C 0 F 1 P25 for low temperature alarm threshold default 10 C 14 F P26 for high temperature alarm threshold default 55 C 131 F c68 for door contact NO NC logic change 0 ON if closed 1 ON if open Con...

Страница 20: ...e table The display shows either OFF or EXX with an icon ashing triangle alternating with the standard display If more than one error occurs these are shown in sequence on the display Failure Code Des...

Страница 21: ...rease scrolling speed press and hold the or button for at least 5 seconds When pressing PRG for 3 seconds the rmware revision code is displayed for 2 seconds When cleaning the controller panel do not...

Страница 22: ...Version No 1 5 09 11 2022 Doc No 9984120001 BZBG 22 28 13 Wiring Diagram Power connector 1 L1 2 3 N 4 PE Signal connector 1 Alarm NC 2 Alarm COM 3 Alarm NO 4 Door contact 5 Door contact...

Страница 23: ...t be protected with a MCB Type D or K Upon connection the internal fan will start working If the temperature inside the enclosure is higher than the set value of the controller both the compressor and...

Страница 24: ...pacity Compressor and external fan work in alternating mode ON OFF Thermal compressor protector triggered Verify if ambient temperature is too high clean condenser Refrigerant leakage Contact dealer s...

Страница 25: ...stopper from in the base of the unit factory setting is locked 1 Dispose the plastic stopper but keep the Slilicon washer 2 Insert the drain socket 3 Lock it clockwise and x the oel cleaning pipe ont...

Страница 26: ...ons Temperature range 40 C to 70 C Relative humidity at 25 C max 95 The cooling unit should always be stored according to the installation position Returning the unit To avoid transport damage the uni...

Страница 27: ...tion manual 1 CE Declaration 1 Mounting template 1 M6 16 bolts 11 A6 4 toothed washers 11 A6 4 washers 11 M4 12 bolts 2 5 pole terminal block for signals 1 4 pole terminal block for electrical connect...

Страница 28: ...Cold air outlet duct AC 8508 12 8412 BZ 1 Anti vibration kit AC 8508 12 8412 T 1 Door switch contact 3100001 Seifert Systems GmbH Seifert Systems Ltd Seifert Systems AG Seifert Systems GmbH Seifert S...

Отзывы: