Seifert 2300110 Скачать руководство пользователя страница 3

Version No. 1-4 - 02.06.2021

Doc. No. 992300110

3 / 13

Disregarding the instruction manual
Operating error
Inappropriate work on or with the unit
The use of non-specified spare parts and accessories
Unauthorised modifications or changes to the unit by the user or his personnel

The supplier is only liable for errors and omissions as outlined in the guarantee conditions contained in the main
contractual agreement. Claims for damages on any grounds are excluded.

3. Safety Instructions

Upon delivery the unit is already meeting current technical standards and can therefore be safely taken into
operation. Only authorised personnel is allowed to work on the unit. Unauthorised personnel must be prohibited
from working on the unit. Operating personnel must inform their superiors immediately of any malfunction of
the unit. 
Please note that before starting to work on or with the unit, a procedure must be carried out inside the cabinet
on which the unit is to be mounted.
Before commencing work inside the cabinet, the control cabinet manufacturer's instruction must be read with
regards to:

Safety instructions.
Instructions on taking the cabinet out of operation.
Instructions on the prevention of unauthorised cabinet reconnection.

The electric equipment meets the valid safety regulations. One can find dangerous voltages (above 50 V AC or
above 100 V DC)

Behind the control cabinet doors.
On the power supply in the unit housing.

The unit has to be operated according to the type plate and the wiring diagram, and must be protected
externally from overloading and electrical faults via suitable protective devices.

  

Danger through incorrect work on the unit
The unit can only be installed and maintained by technical competent and qualified
personnel, using only supplied material according to the supplied instructions.

 

Danger from electrical voltage
Only specialised personnel are allowed to maintain and clean the unit. The personnel must
ensure that for the duration of the maintenance and cleaning, the unit is disconnected from
the electrical supply.

 

Attention
Damage to the unit through the use of inappropriate cleaning materials. Please do not use
aggressive cleaning material.
 

 

Instruction
Damage to the environment through unauthorised disposal. All spare parts and associated
material must be disposed according to the environmental laws.

Содержание 2300110

Страница 1: ...l Regulations 2 3 Safety Instructions 3 4 Settings 4 5 Functional Principle 5 6 Technical Data 6 7 Mounting 7 8 Mounting Principle 9 9 Wiring Diagram 10 10 Taking into Operation 11 11 Maintenance Clea...

Страница 2: ...ns in the instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a speci c pictogram such as one of the following High electric voltage I...

Страница 3: ...with regards to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid safe...

Страница 4: ...55 P The cooling water used must be soft enough to avoid scale deposits but should not be too soft as this would corrode the heat exchanger Where the cooling water is cooled for reuse part of the wate...

Страница 5: ...s constantly providing continuous circulation of the air in the cabinet This circulation prevents hot spots within the control cabinet During this process the coolant heats up and is returned to the c...

Страница 6: ...peded 85 240 m h Mounting Wall mounted recessed Housing Material Mild steel powder coated Dimension A x B x C D E 303 x 153 x 84 mm Weight 4 5 kg Voltage Frequency 120 V 60 Hz Starting Current 0 74 A...

Страница 7: ...g template enables the unit to be installed quickly For mounting the template should be attached to the wall of the cabinet and the holes for the xing screws should be drilled in the wall of the cabin...

Страница 8: ...ion drain pipe should be attached as required e g in conditions of high humidity To install an oel cleaning drain 2 pipe please follow below steps Remove the plastic stopper from in the base of the un...

Страница 9: ...Version No 1 4 02 06 2021 Doc No 992300110 9 13 8 Mounting Principle 1 Bolt 2 Toothed washer 3 Washer 4 Enclosure 5 Mounting gasket...

Страница 10: ...Version No 1 4 02 06 2021 Doc No 992300110 10 13 9 Wiring Diagram M1 Radial fan X3 3 pin connector L1 Live N Neutral PE Earth protection...

Страница 11: ...the unit To set the ow rate Q turn the thermostatic head Set the indicator position to the required cabinet temperature The work s setting of the water ow regulator is 35 C The adjustment range is 20...

Страница 12: ...ure If no button is pressed for 60 sec all changes made to the parameters temporarily saved in the RAM will be cancelled and the previous settings restored The cooling unit manufacturer is in no way l...

Страница 13: ...ned in the original packing or in a packing case and must be strapped to a pallet If the unit cannot be returned in the original packing please ensure that A space of at least 30 mm must be maintained...

Отзывы: