5 Permitted loads
14
5.3
Galeo S and Galeo S Sub with Galeo S Flying Frame
The Galeo S Flying Frame can be used to fly up to a maximum of 20 Galeo S line array units, nine
Galeo S Sub or combinations of three Galeo S Sub and nine Galeo S. The actually permitted num-
ber of elements is, however, dependent on the vertical angle (down tilt) of the array and the pin
point in use. The vertical angle is dependent on the length of the array, the pin point and the curv-
ing of the array. The Cradle is always at an angle of 0° to the uppermost Galeo S element, so
therefore the Cradle angle (or Frame angle) is automatically the vertical angle of the uppermost
element/subwoofer in the array.
It is recommended to simulate the desired system configuration using the EASE Focus 3 software
and use the following table to check whether the combination of the number of elements, the pin
point and the maximum downtilt is permissible.
Permitted no. of Galeo S
Pinpoint
Max. do/- 5°
Max. do/- 5-15°
Max. do/- 15-30°
1 - 19
20
20
20
20
20
20
19
21
20
20
18
22
20
20
17
23
20
20
16
24
20
20
15
25
20
20
15
26
20
20
14
Example: For a flown array of 16 Galeo S units, the pin point must be 23 or lower if the curving of